MDX61B0008-5A3-4-00 SEW MOVIDRIVE
May 28, 2026

MDX61B0008-5A3-4-00 SEW MOVIDRIVE

MDX61B: High‑performance vector/servo drive, 2 option slots, closed‑loop vector / servo capable. 0008: Rated motor power 0.75 kW. 5A3: 3‑phase 380–500 V AC, integrated Class C2 EMC filter. 4: 4‑quadrant operation, built‑in brake chopper. 00: Standard version(non‑coated PCB, basic IPOSplus® positioning only).

Description

1. Model Meaning

  • MDX61B: High‑performance vector/servo drive, 2 option slots, closed‑loop vector / servo capable.

  • 0008: Rated motor power 0.75 kW.

  • 5A3: 3‑phase 380–500 V AC, integrated Class C2 EMC filter.

  • 4: 4‑quadrant operation, built‑in brake chopper.

  • 00: Standard version(non‑coated PCB, basic IPOSplus® positioning only).


2. Electrical Ratings

  • Input: 3×380–500 V AC ±10 %, 50/60 Hz; rated input current 2.4 A.

  • Output: 0.75 kW, apparent power 1.7 kVA, rated current 2.4 A.

  • Output frequency: 0–599 Hz.

  • Overload: 200 % IN / 60 s, 175 % IN / 2 s.

  • PWM frequency: 4/8/16 kHz (default 4 kHz).

  • Brake chopper: integrated; external resistor ≥ 68 Ω required.


3. Control & Performance

  • Control modes:

    VFC (open‑loop volts‑per‑hertz)

    CFC (closed‑loop vector)

    Servo control (with encoder option)

  • Safety: STO (Safe Torque Off), PL d compliant.

  • Motion: IPOSplus® basic positioning, flying restart, DC braking, PID.

  • Options: encoder card, fieldbus (PROFINET, EtherNet/IP, CANopen).


4. I/O & Communication

  • Analog inputs: ±10 V / 4–20 mA.

  • Digital: 24 V DC isolated inputs; programmable outputs (transistor + 1 relay); motor thermistor input.

  • Standard interfaces: SBus, RS485 (Modbus RTU).


5. Mechanical & Environmental

  • Protection: IP20 (cabinet mount).

  • Cooling: temperature‑controlled fan.

  • Ambient: 0 °C to +50 °C (derate >40 °C); storage −25 °C to +70 °C.

  • Dimensions (W×H×D): 105 × 260 × 95 mm.

  • Weight: approx. 3.1 kg.

  • PCB: non‑coated (standard industrial environments).


6. Protection Functions

  • Overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short‑circuit.

  • Motor overtemperature via thermistor.

  • Alarms & safe stop; fault codes on built‑in display.


7. Applications

  • Conveyors, packaging, material handling, pumps/fans, general automation.

  • For dry, clean environments (non‑coated PCB).


8. Certifications

  • CE, UL 508C, CSA, RoHS; meets EN 61800‑3 (EMC), EN 60204‑1 (safety).


9. 00 vs 0T

  • 00: standard, non‑coated PCB, basic positioning only.

  • 0T: coated PCB, electronic cam, synchronous control, extended IPOSplus®.