MDX61A0370-503-4-00
Description
1. Model Code Explanation
MDX61A: MOVIDRIVE MDX61A high-performance AC drive series
0370: Rated output power 37 kW
5: 3-phase input voltage 380 V ~ 500 V AC
03: Version without built-in EMC/RFI filter
4: Integrated brake chopper for 4-quadrant operation
00: Standard hardware configuration with uncoated PCB
2. Electrical Specifications
Mains Input
Voltage range: 3×380 V (-10%) to 3×500 V (+10%)
Frequency: 50/60 Hz ±5%
Rated input current: 65.7 A
Motor Output
Rated power: 37 kW
Apparent power: 51.1 kVA
Rated output current: 73 A (4 kHz PWM)
Output voltage: 0 to full input voltage
Output frequency: 0–400 Hz (general mode), up to 599 Hz (vector mode)
Overload capability: 150% rated current for 60 seconds, 175% rated current for 2 seconds
Adjustable PWM frequency: 4 kHz, 8 kHz, 16 kHz
Brake chopper: Integrated; external braking resistor is required
3. Control & Main Functions
Control modes: VFC sensorless vector control, CFC encoder-based vector control, servo control
Built-in IPOSplus® for positioning and sequence control, supporting single-axis positioning, synchronization and winding applications
Safety function: STO (Safe Torque Off) compliant with PL d
Motor protection: Compatible with PTC and KTY thermistor sensors
Additional functions: Automatic motor tuning, flying restart, DC braking
4. I/O and Communication
Analog input: 0–10 V / -10 V ~ +10 V for speed reference
Digital inputs: 8 channels of 24 V DC isolated inputs
Digital outputs: 5 transistor outputs + 1 programmable relay output
Standard interfaces: SBus, RS485 (Modbus RTU)
Optional expansion: Profibus DP, EtherNet/IP and other communication modules
5. Mechanical & Environmental Conditions
Protection class: IP20 (cabinet installation)
Cooling method: Forced air cooling with temperature-controlled fan
Operating temperature: 0 °C ~ +40 °C. Power derating is required above 40 °C
Storage temperature: -25 °C ~ +70 °C
Weight: Approximately 27 kg
Dimensions (W × H × D): 280 × 520 × 307 mm
6. Protection Functions
7. Application Scope
8. Certifications & Standards
CE, UL 508C, CSA and RoHS compliant
Conforms to EN 61800-3 and EN 60204-1
9. Model Difference
00: Standard uncoated PCB, for regular indoor environments
0T: Anti-corrosion coated PCB, for humid or corrosive working environments
Get a Quote