MDX60B0014-5A3-4-0T
May 28, 2026

MDX60B0014-5A3-4-0T

Model Code Explanation MDX60B: MOVIDRIVE MDX60B compact AC drive series 0014: Rated output power 1.5 kW 5: 3-phase input voltage 380 V ~ 500 V AC A3: Built-in Class C2 EMC/RFI filter 4: Integrated brake chopper for 4-quadrant operation 0: Standard hardware configuration with uncoated PCB

Description

1. Model Code Explanation

  • MDX60B: MOVIDRIVE MDX60B compact AC drive series

  • 0014: Rated output power 1.5 kW

  • 5: 3-phase input voltage 380 V ~ 500 V AC

  • A3: Built-in Class C2 EMC/RFI filter

  • 4: Integrated brake chopper for 4-quadrant operation

  • 0: Standard hardware configuration with uncoated PCB

2. Electrical Specifications

Mains Input

  • Voltage range: 3×380 V (-10%) to 3×500 V (+10%)

  • Frequency: 50/60 Hz ±5%

  • Rated input current: 3.6 A

Motor Output

  • Rated power: 1.5 kW

  • Apparent power: 2.8 kVA

  • Rated output current: 4.0 A

  • Output voltage: 0 to full input voltage

  • Output frequency: 0–180 Hz (VFC mode), 0–500 Hz (vector mode)

  • Overload capability: 200% rated current for 60 seconds

  • PWM frequency: 4 kHz (default), adjustable to 8 kHz, 12 kHz, 16 kHz

  • Brake chopper: Integrated for regenerative loads

3. Control & Main Functions

  • Control modes: VFC sensorless V/F control, CFC encoder-based vector control

  • Safety function: STO (Safe Torque Off) compliant with PL d

  • Built-in functions: Automatic motor tuning, flying restart, DC braking, PID regulation, IPOSplus® positioning function

  • Motor protection: Supports PTC/TF/TH/KTY thermistor input

4. I/O and Communication

  • Analog input: 0–10 V / -10 V ~ +10 V for speed reference

  • Digital inputs: 8 isolated 24 V DC inputs

  • Digital outputs: 5 transistor outputs + 1 programmable relay output

  • Standard interfaces: SBus, RS485 (Modbus RTU)

  • No optional expansion slots

5. Mechanical & Environmental Conditions

  • Protection class: IP20 (cabinet mounting)

  • Cooling method: Natural convection without fan

  • Operating temperature: 0 °C ~ +40 °C; full power available up to 50 °C at 4 kHz PWM

  • Storage temperature: -25 °C ~ +70 °C

  • Weight: Approximately 2.43 kg

  • Dimensions (W × H × D): 45 × 317 × 260 mm

6. Protection Functions

Equipped with overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short circuit and motor overheat protection. It activates alarms and executes safe stop once faults are detected. Status and fault codes are shown on the 7-segment display.

7. Application Scope

Suitable for small conveyors, fans, pumps, packaging machinery and general light-duty automation equipment. The built-in EMC filter facilitates easy installation. This standard version is designed for normal indoor environments.

8. Certifications & Standards

  • CE, UL 508C, CSA and RoHS compliant

  • Conforms to EMC standard EN 61800-3 (Class C2)

9. Model Difference

  • 0: Standard uncoated PCB, for regular indoor environments

  • 0T: Anti-corrosion coated PCB, for humid or corrosive working conditions