MDX60B0005-5A3-4-00
Description
1. Model Code Explanation
MDX60B: MOVIDRIVE MDX60B series compact AC drive
0005: Rated output power 0.55 kW (0.75 HP)
5: 3-phase input voltage 380 V to 500 V AC
A3: Integrated EMC/RFI filter (Class C2)
4: Integrated brake chopper, 4-quadrant operation
00: Standard hardware configuration
2. Electrical Specifications
Input
Voltage: 3×380 V (-10%) ~ 3×500 V (+10%)
Frequency: 50/60 Hz ±5%
Rated input current: 1.8 A
Output
Rated power: 0.55 kW
Apparent power: 1.4 kVA
Rated output current: 2.0 A
Max. controller current: 4.0 A
Output voltage: 0 to rated input voltage
Output frequency: 0–180 Hz (VFC), 0–500 Hz (vector)
Overload capacity: 200% load for 60 s (Size 0)
PWM frequency: 4 kHz (default), adjustable
Brake chopper: Integrated (standard)
3. Control Functions & Performance
Control modes: VFC (sensorless V/F), CFC (encoder vector)
Speed range: -6000 to +6000 rpm; resolution 0.2 rpm
Built-in functions: Auto-tuning, flying restart, energy saving, DC braking, PID controller
Safety: STO (Safe Torque Off) per EN 61800-5-2
4. I/O & Communication
Analog input: 0–10 V / -10 V~+10 V (speed reference)
Digital inputs: 8×24 V DC (isolated)
Digital outputs: 5×transistor, 1×relay (programmable)
Motor thermistor input: PTC/TF/TH/KTY
Standard: SBus, RS485 (Modbus RTU)
Optional: Profibus DP, CANopen, Ethernet/IP, EtherCAT
5. Mechanical & Environmental
Protection class: IP20 (cabinet installation)
Cooling: Natural convection (no fan)
Operating temp: 0 °C to +40 °C; full power up to 50 °C (4 kHz)
Storage temp: -25 °C to +70 °C
Weight: approx. 2.0 kg
Dimensions (W×H×D): 45 × 317 × 260 mm
6. Protection Functions
Overcurrent, overvoltage, undervoltage, overtemperature
Ground fault, short circuit, motor overheat, fast current limit
Alarm & safe stop on fault; 7-segment display for status/faults
7. Application Scope
Small conveyors, fans, pumps, packaging machines, lab equipment
Light-duty, constant or quadratic loads; built-in EMC filter simplifies installation
8. Certifications & Standards
CE, UL 508C, CSA, RoHS compliant
Meets EN 61800-3 (EMC), EN 60204-1, Class C2 (input)
9. Model Distinction
5A3: With built-in EMC filter (standard for Size 0)
503: Without built-in filter (external required)
Get a Quote