MDX60A-0150-503-4
May 28, 2026

MDX60A-0150-503-4

Model Code Definition MDX60A: MOVIDRIVE MDX60A series AC drive unit 0150: Rated output power 15 kW 5: 3-phase AC input, voltage range 380 V ~ 500 V 03: Standard version without built-in EMC/RFI filter 4: Integrated brake chopper, supports 4-quadrant operation

Description

1. Model Code Definition

  • MDX60A: MOVIDRIVE MDX60A series AC drive unit

  • 0150: Rated output power 15 kW

  • 5: 3-phase AC input, voltage range 380 V ~ 500 V

  • 03: Standard version without built-in EMC/RFI filter

  • 4: Integrated brake chopper, supports 4-quadrant operation

2. Electrical Parameters

Mains Input

  • Operating voltage: 3×380 V (-10%) to 3×500 V (+10%)

  • Input frequency: 50/60 Hz ±5%

  • Rated input current: 28.5 A

Motor Output

  • Rated output power: 15 kW

  • Apparent power: 22.8 kVA

  • Rated output current: 32 A (4 kHz PWM)

  • Output voltage: 0 up to full input voltage

  • Output frequency: 0–180 Hz (VFC mode); 0–500 Hz (vector mode)

  • Overload capability: 125% rated load for 60 seconds, 150% rated load for 3 seconds

  • Adjustable PWM frequency: 4 kHz, 8 kHz, 16 kHz

  • Brake chopper: Integrated for regenerative load handling

3. Control & Main Functions

  • Control modes: VFC sensorless voltage/frequency control, CFC encoder-based vector control

  • Speed range: -6000 rpm to +6000 rpm, speed resolution: 0.2 rpm

  • Automatic motor parameter identification

  • Flying restart function for running motors

  • Energy saving mode for light load operation

  • Excellent speed stability and dynamic response

4. I/O and Communication

  • Analog input: 0–10 V / -10 V ~ +10 V for speed setpoint

  • Multiple programmable 24 V DC digital inputs and relay outputs

  • Dedicated interface for motor thermistor thermal protection

  • Standard SBus system bus; optional expansion for Profibus DP, CANopen and Modbus RTU

5. Mechanical and Environmental Data

  • Protection class: IP20 (cabinet installation)

  • Cooling type: Forced air cooling with temperature-controlled fan

  • Operating ambient temperature: 0 °C ~ +40 °C. Power derating 2% per °C above 40 °C

  • Storage temperature: -25 °C ~ +70 °C

6. Protection Functions

Full protection including overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short circuit and motor overheat. The drive will activate alarm and execute safe stop once faults are detected.

7. Typical Applications

Conveyor systems, lifting equipment, packaging machinery, pumps, fans and other industrial devices with frequent deceleration and regenerative loads.

8. Compliance & Certifications

Compliant with CE, UL 508C, CSA and RoHS. Meets the standards EN 61800-3 and EN 60204-1.


Get a Quote