MDV60A0220-503-4-07 (SEW MOVIDRIVE MDV60A Inverter)
Description
Technical Specifications
Input: 3-phase AC 380–500 V, 50/60 Hz, 41.4 A
Output: 22.0 kW, 46.0 A, 51.7 kVA, frequency range: 0–180 Hz
Control modes: VFC (open-loop vector control), CFC (closed-loop vector control with encoder)
Overload capability: 150% rated load for 60 seconds; 200% rated load for 3 seconds
Protection class: IP20
Ambient temperature: 0 °C to +40 °C for full load operation
Dimensions (Width × Height × Depth): 200 × 470 × 221 mm
Weight: 15.0 kg
Key Features
No integrated RFI filter, suitable for systems equipped with external EMC devices
4-quadrant design realizes fast braking and energy recovery
Revised control unit maintains identical performance and compatibility with standard models
Supports PROFIBUS, CANopen, Modbus and SBus communication protocols
Comprehensive protection against overvoltage, overcurrent, overtemperature, stall and earth fault
Typical Applications
Heavy-duty conveyors and bulk material handling equipment
Industrial fans, pumps and heavy processing machinery
General industrial automation systems with external EMC solutions
Speed and torque control for high-power asynchronous motors
Related Model Variants
MDV60A0220-503-4-00: 22.0 kW, no RFI filter, standard version
MDV60A0220-503-4-0T: 22.0 kW, no RFI filter, preloaded application firmware
MDV60A0220-5A3-4-07: 22.0 kW, with integrated RFI filter, revised control unit version
Get a Quote