MC07B0040-5A3-4-S0
May 27, 2026

MC07B0040-5A3-4-S0

This is a 4.0 kW three-phase frequency inverter integrated with STO (Safe Torque Off) safety function. It is equipped with a built-in brake chopper for 4-quadrant operation, and intended for speed regulation of three-phase asynchronous motors in industrial applications that require functional safety.

Description

1. General Description

This is a 4.0 kW three-phase frequency inverter integrated with STO (Safe Torque Off) safety function. It is equipped with a built-in brake chopper for 4-quadrant operation, and intended for speed regulation of three-phase asynchronous motors in industrial applications that require functional safety.

2. Model Code Explanation

  • MC07B: MOVITRAC B series

  • 0040: Rated motor power 4.0 kW

  • 5: 3-phase input voltage 380–500 V AC

  • A: No integrated EMC filter; an external C2 filter is required

  • 3: Three-phase power input

  • 4: 4-quadrant operation with integrated brake chopper

  • S0: Built-in STO (Safe Torque Off) safety function

3. Technical Specifications

Electrical Data

  • Input: 3 × AC 380–500 V (±10%), 50/60 Hz

  • Rated power: 4.0 kW (5.4 HP)

  • Rated output current: 9.5 A

  • Output: 3 × AC 0–480 V; Frequency range: 0–600 Hz (V/f mode), 0–150 Hz (VFC mode)

  • Overload capability: 125% rated current for continuous operation; 150% rated current for 60 seconds

  • Control modes: V/f control, sensorless VFC vector control

  • Communication: Onboard RS485 interface supporting Modbus RTU

  • EMC: No internal filter. External C2 EMC filter is needed to meet relevant standards

  • Safety: STO function compliant with PL d / SIL 2

Mechanical & Environmental Data

  • Protection class: IP20, suitable for cabinet installation

  • Cooling method: Natural air convection

  • Dimensions (W × H × D): 80 × 273.5 × 163.5 mm

  • Weight: Approximately 2.1 kg

  • Operating temperature: -10 °C to +50 °C. Power derating is required above 50 °C

  • Altitude: Derate 1% per 100 m above 1000 m, maximum altitude 2000 m

  • Certifications: CE, UL, cUL, RoHS

I/O and Protection Functions

  • I/O configuration: 6 digital inputs, 2 digital outputs, 1 relay output, 1 analog input (0–10 V / 4–20 mA)

  • Motor monitoring: Support for TF / PTC / TH temperature detection

  • Protection functions: Overcurrent, overvoltage, undervoltage, overtemperature, motor overload, short-circuit and earth fault protection

4. Key Features

  1. Integrated STO safety function ensures safe machine shutdown for safety-related applications.

  2. Built-in brake chopper enables reliable 4-quadrant operation for inertial and regenerative loads.

  3. Dual control modes to satisfy different motor speed control requirements.

  4. Standard Modbus RTU communication for easy connection to automation systems.

  5. Compact design and natural convection cooling for convenient installation and maintenance.

5. Applications

It is widely used for 4.0 kW three-phase asynchronous motors on conveyors, fans, water pumps, mixers, packaging machines and other industrial equipment where safety stop function is required.


Get a Quote