MC07B0011-5A3-4-S0
Description
1. General Description
2. Model Code Explanation
MC07B: MOVITRAC B series
0011: Rated motor power 1.1 kW
5: Input voltage 3×AC 380–500 V
A: No EMC filter (external filter required for EMC compliance)
3: Three‑phase input
4: 4‑quadrant operation, integrated brake chopper
S0: Safe Torque Off (STO) safety function (EN ISO 13849‑1 PL d)
3. Technical Specifications
Electrical Data
Input: 3×AC 380–500 V (±10%), 50/60 Hz
Rated power: 1.1 kW (1.5 HP)
Rated output current: 3.1 A
Output: 3×AC 0–500 V, 0–600 Hz (V/f) / 0–150 Hz (VFC)
Overload capability: 125% continuous; 150% / 60 sSEW-EURODRIVE
Control modes: V/f, sensorless VFC vector control
EMC: No integrated filter (external C2 filter recommended)
Mechanical & Environmental
Protection class: IP20 (cabinet installation only)
Cooling: Natural convection
Dimensions (W × H × D): 80 × 273.5 × 163 mm
Weight: ≈ 1.8 kg
Ambient temperature: −10 °C to +50 °C (derate above 50 °C)
I/O & Safety
I/O: 6DI, 2DO, 1 relay output, 1AI
Safety: STO (S0) – safe torque off, PL d
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, motor overload, short circuit, earth fault
4. Key Features
STO (S0) safety function for safe motor shutdown
4‑quadrant operation with built‑in brake chopper
Compact size for cabinet installation
Wide frequency range up to 600 Hz
RS485 (Modbus RTU) communication as standard
5. Applications
6. Difference from MC07B0011-5A3-4-00
‑S0: Includes STO safety function (PL d)
‑00: Standard version without STO
Get a Quote