MC07B0005-5A3-4-00
May 27, 2026

MC07B0005-5A3-4-00

Compact 3‑phase 380–500 V frequency inverter from the MOVITRAC B‑series, rated 0.55 kW, for controlling standard asynchronous motors in light industrial applications.

Description

1. General Description

Compact 3‑phase 380–500 V frequency inverter from the MOVITRAC B‑series, rated 0.55 kW, for controlling standard asynchronous motors in light industrial applications.

2. Model Code Explanation

  • MC07B: MOVITRAC B‑series

  • 0005: Rated motor power 0.55 kW

  • 5: Input voltage 3×AC 380–500 V

  • A: Integrated Class A EMC filter

  • 3: 3‑phase input

  • 4: 4‑quadrant operation with integrated brake chopper

  • 00: Standard version (no STO, no option card)

3. Technical Specifications

Electrical Data

  • Input: 3×AC 380–500 V, 50/60 Hz

  • Rated power: 0.55 kW (0.74 HP)

  • Rated output current: 2.0 A

  • Output: 3×AC 0–599 V, 0–599 Hz

  • Overload capability: 125% continuous; 150% / 60 s

  • Control modes: V/f, sensorless VFC vector control

  • EMC: Built‑in Class A filter (EN 61800‑3 C2)

Mechanical & Environmental Data

  • Protection class: IP20 (cabinet mount)

  • Cooling: Natural convection

  • Dimensions (W×H×D): 54.5 × 185 × 163.5 mm

  • Weight: ≈1.5 kg

  • Frame size: 0S

  • Ambient temperature: −10 °C to +50 °C

I/O & Protection

  • I/O: 6DI, 2DO, 1 relay, 1AI

  • Protection: Overcurrent, overvoltage, undervoltage, overtemperature, motor overload, short‑circuit, earth fault

4. Key Features

  1. 3‑phase 400 V input for 0.55 kW motors

  2. Integrated Class A EMC filter (no external filter needed for C2)

  3. Built‑in brake chopper for 4‑quadrant operation

  4. 0S compact size for space‑saving installation

5. Applications

Small fans, pumps, conveyors, and general‑purpose 0.55 kW three‑phase motors supplied from 380–500 V industrial grids.

6. Difference from MC07B0005-2B1-4-00

  • Voltage: 5A3 = 3×400 V; 2B1 = 1×230 V

  • Filter: A = Class A; B = Class B

  • Phase: 3 = 3‑phase input; 1 = single‑phase input

  • Current: 2.0 A (400 V) vs 3.3 A (230 V)


Get a Quote