370-503-4-00
Description
Model Code Definition
370: Rated power 37 kW, rated output current 75 A
503: 3-phase 380–500 V AC input, without integrated EMC filter
4: 4-quadrant operation with regenerative braking
00: Standard configuration, no STO, no fieldbus interface
Technical Parameters
Input
Rated voltage: 3-phase AC 380–500 V (±10%)
Frequency: 50 / 60 Hz (±10%)
Rated input current: 69 A @ 400 V
Output
Rated power: 37 kW (50 HP)
Rated output current: 75 A @ 400 V
Apparent power: 52 kVA
Frequency range: 0–400 Hz
Overload capability: 150% rated current for 60 s; 180% rated current for 2 s
Control & Interfaces
Control modes: V/F open-loop, sensorless vector control
Digital I/O: 7 inputs, 2 outputs, 1 relay output
Analog I/O: 2 inputs, 2 outputs
Safety feature: No STO
Protection functions: Overcurrent, overvoltage, undervoltage, overtemperature, earth fault, short circuit
Mechanical & Environmental
Protection class: IP20
Operating temperature: 0 °C ~ +45 °C
Storage temperature: -25 °C ~ +70 °C
Dimensions (W×H×D): 220 × 550 × 265 mm
Weight: 21.8 kg
Main Features
Energy regeneration design recycles braking energy to the grid and eliminates external brake resistors.
Dual control modes deliver stable speed and torque for motor operation.
Compact structure, easy to install in standard control cabinets.
Complete protection system ensures reliable operation in industrial scenarios.
Application Scope
Relevant Models
31C370-503-4-05: Standard temperature, with STO, no fieldbus
31C370-503-4-07: Wide temperature range, no STO, no fieldbus
31C370-503-4-20: Standard temperature, with PROFIBUS-DP, no STO
31C370-503-4-25: Standard temperature, with PROFIBUS-DP and STO
Get a Quote