1130-403-4-00
Description
1. Model Code Explanation
1130:Power size, 5.5 kW
403:3×AC 380–500 V, no built‑in EMC filter
4:Four‑quadrant operation (regenerative braking)
00:Standard firmware, no fieldbus, no STO
2. Main Technical Data
Input:3×AC 380–500 V (‑30%/+30%), 50/60 Hz
Output:3×0–400 V, 2–127.5 Hz, 12 A, for 5.5 kW motor
Rated power:5.5 kW (7.5 HP)
Control modes:V/f open‑loop, sensorless vector (VFC)
Overload:125% continuous, 150% for 60 s
I/O:6DI / 2DO / 1 relay;2AI / 2AO
Protection:Overcurrent, overvoltage, undervoltage, overtemperature, earth fault
Enclosure:IP20
Ambient temp:0 °C ~ +45 °C
Weight:approx. 8.5 kg
3. Key Features
✅ Four‑quadrant + regenerative braking:handles overhauling/feedback loads (lifting, conveyors)
✅ 3×400 V industrial supply:external EMC filter required for Class C2
✅ Sensorless vector control:no encoder needed, lower cost
✅ Compact, rugged design for continuous duty
4. Typical Applications
Lifting equipment, cranes, conveyors with regenerative loads
Fans, pumps, compressors requiring fast deceleration
General industrial machinery with 5.5 kW 3‑phase motors
5. vs. 1130-403-1-00
1130-403-4-00:Four‑quadrant, regenerative braking, for dynamic/feedback loads
1130-403-1-00:One‑quadrant, no braking, cost‑effective for standard loads
Get a Quote