1008-231-4-00
Description
1. Model Decoding
1008: Size/power rating(1.5 kW, 1.6 kVA)
231: 1×AC 230 V, no built‑in EMC filter
4: 4‑quadrant operation(with regenerative braking)
00: Standard firmware, no fieldbus, no STO
2. Key Specifications
Input: 1×AC 230 V(−30% / +15%), 50/60 Hz
Output: 3×0–230 V, 2–127.5 Hz, 4.0 A, for 1.5 kW motor
Power: 1.6 kVA, 1.5 kW
Control: V/f open‑loop, sensorless vector(VFC)
Overload: 125% continuous, 150% for 60 s
I/O: 6DI / 2DO / 1 relay, 2AI / 2AO
Protection: Overcurrent, overvoltage, undervoltage, overtemperature, earth fault
Enclosure: IP20
Ambient Temp: 0 °C to +45 °C
Dimensions: Approx. 184 × 127 × 76 mm
Weight: Approx. 5.4 kg
3. Features
✅ 4‑quadrant & regenerative braking:ideal for overhauling/deceleration loads
✅ 1‑phase 230 V input:suitable for single‑phase power supply scenarios
✅ No integrated EMC filter:external filter required for C2 compliance
✅ Sensorless vector control:no encoder, saves wiring cost
✅ Compact & rugged:heavy‑duty housing for harsh environments
4. Typical Applications
Conveyors, fans, pumps with frequent deceleration/overhauling
Packaging, textile, woodworking machinery
Small lifting equipment(regenerative braking beneficial)
General light‑duty industrial drives(1.5 kW, single‑phase)
5. Difference vs 1008-231-1-00
1008-231-4-00: 4‑quadrant, regen braking, for active loads