RS-091/A
Model: RS-091/A
Brand: KEBA
Type: Rack-mounted industrial power supply module
Application: KEMRO K2 series control system, injection molding machine and automation equipment
Installation: Standard control cabinet rack slot installation
Protection Class: IP20
Description
1. General Information
Model: RS-091/ABrand: KEBAType: Rack-mounted industrial power supply moduleApplication: KEMRO K2 series control system, injection molding machine and automation equipmentInstallation: Standard control cabinet rack slot installationProtection Class: IP20
2. Electrical Specifications
Input voltage: 110V/230V AC automatic adaptiveInput frequency: 50/60HzOutput voltage: Stable 24V DCRated output current: 10AOutput power: 240WProtection features: Over voltage, under voltage, overload, short circuit, reverse polarity protectionLow ripple output, high stability and high conversion efficiency
3. Core Functions
Supply standard 24V DC power for entire system CPU, bus and I/O modules
Built-in EMC filter to suppress external electromagnetic interference
Equipped with power running indicator and fault alarm indicator
Centralized power supply distribution for internal cabinet control components
Support long-term continuous stable operation under industrial environment
4. Environmental Conditions
Operating temperature: 0℃ ~ +50℃Storage temperature: -40℃ ~ +85℃Relative humidity: 5% ~ 95% RH, non-condensingAdequate ventilation and heat dissipation space is required
5. Compatible Equipment
Fully compatible with KEMRO-K2-200, KEMRO-K2-400 main controllerMatch KEMRO-BUS-8, PD-242/A backplane modulesAdapt to DC162, FB201 and other KEBA series expansion modules
6. Installation Guide
Cut off all AC power supply before operation
Insert the module into designated rack slot and fix tightly
Connect AC input terminal and 24V DC output terminal correctly
Separate high voltage circuit and low voltage signal wiring
Confirm all connections are correct then power on for inspection
7. Safety Notice
Only qualified professional technicians are allowed to install and maintain.Do not disassemble or modify internal structure without permission.Prohibit overload operation beyond rated parameters.Regularly check heat dissipation status and wiring firmness to extend service life.