XYCOM 4800-E7 (Modbus Protocol Expansion Card) Product Description

作者:小编 更新时间:2026-05-20 点击数:

XYCOM 4800-E7 (Modbus Protocol Expansion Card) Product Description

I. Product Overview

XYCOM 4800-E7 is an industrial-grade Modbus protocol expansion card launched by XYCOM (now part of Schneider Electric), specifically designed for the XYCOM 4000 series (4153B/4153C, etc.) industrial HMI / workstation, to expand the standard Modbus communication interface and enable stable data interaction with PLCs, DCSs, instruments, etc. It is widely used in upgrading old industrial systems, networking multiple devices, and protocol conversion scenarios.

II. Core Positioning and Naming Explanation

Official Model: 4800-E7;

Product Type: ISA Bus Modbus Protocol Expansion Card;

Compatible Platform: XYCOM 4000 series industrial workstations (4153B/4153C/4163);

Core Function: To extend the native Modbus RTU/ASCII communication capability of XYCOM industrial terminals, without the need for additional gateways, directly connect to the Modbus network, and meet the integration requirements of legacy control systems.

III. Core Functions

Standard Modbus Protocol Support, Seamless Integration with Industrial Equipment

Native support for Modbus RTU (master / slave stations), Modbus ASCII protocol, compatible with mainstream PLCs (such as Allen-Bradley, Siemens, Mitsubishi), DCSs, temperature / pressure instruments, frequency converters, etc.; supports register reading and writing, coil control, status query, etc. standard Modbus function codes, meeting the requirements of industrial field data acquisition and equipment control.

ISA Bus Plug-and-Play, Compatible with XYCOM 4000 Series

Uses standard ISA bus interface, directly inserted into the ISA expansion slot of XYCOM 4153B/4153C and other terminals, no additional drivers (DOS/Windows system native support), plug-and-play; onboard hardware communication chip, does not occupy the CPU resources of the host, communication stable and efficient.

Multi-Serial Port Isolation Design, Strong Anti-interference

Provides 1 independent RS-232/422/485 switchable serial port, built-in optical isolation (2500Vrms), surge protection, ESD protection, effectively resisting electromagnetic interference generated by frequency converters, motors, etc. in industrial environments; RS-485 supports multi-node networking (up to 32 slave stations), communication distance up to 1200 meters (9600bps).

Wide Temperature Industrial-grade Design, Compatible with Harsh Environments

Uses industrial-grade components, reinforced PCB board, metal shielding cover, operating temperature -20℃ to +60℃, storage temperature -40℃ to +70℃, compatible with high-temperature, low-temperature, dusty, humid industrial environments; supports 24-hour continuous operation, fault-free operation time (MTBF) ≥ 50,000 hours.

Simple Configuration and Debugging, Reducing Maintenance Costs

Provides DOS configuration tool, Windows driver, supports serial port parameters (baud rate: 1200–115200bps, data bits / parity bits / stop bits), Modbus address, master-slave station mode quick configuration; onboard LED indicator lights (power / sending / receiving / fault), real-time display of communication status, facilitating quick troubleshooting.

IV. Technical Parameters (Official Standard Specifications)

Model: 4800-E7;

Bus Interface: Standard ISA Bus (16 bits); Communication Protocol: Modbus RTU (Master/Slave Station), Modbus ASCII;

Serial Port Configuration:

Interface Type: 1×DB9 (RS-232/422/485 switchable);

Baud Rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps;

Data Bits: 7/8;

Parity: None, Odd, Even;

Stop Bits: 1/2;

Isolation Voltage: 2500Vrms (Optical Isolation);

Protection Mechanism: Surge, ESD, Overcurrent Protection.

Hardware Characteristics:

Communication Chip: Industrial-grade UART Controller;

On-board Cache: 16KB (Data Reception and Transmission Cache);

Indicators: PWR (Power), TX (Transmit), RX (Receive), ERR (Fault);

Size: Standard ISA Half-Length Card (170mm×100mm);

Weight: Approximately 0.2kg.

Electrical Characteristics:

Power Supply: +5V DC (Powered by ISA Bus, No External Power Required);

Power Consumption: Typical ≤5W;

Insulation Resistance: ≥10MΩ (500V DC).

Environmental Parameters:

Operating Temperature: -20℃ to +60℃;

Storage Temperature: -40℃ to +70℃;

Humidity: 10% to 95% RH (No Condensation);

Vibration: 5–200Hz, 0.5g Sinusoidal Vibration;

Impact: 10g Peak Impact (Half-Sinusoidal Wave, 11ms).

Certifications: CE, UL 508, RoHS.

VII. Mechanical and Environmental Characteristics

Standard ISA Half-Length Card Design, Easy Installation

Adopts industrial standard ISA Half-Length Card size (170mm×100mm), compatible with ISA expansion slots of terminals such as XYCOM 4153B/4153C; No fixing screws required, insert and fix directly, installation / disassembly only takes 1 minute, maintenance is efficient.

Metal Shielding + Optical Isolation, Strong Anti-Interference

The card body adopts a metal shielding cover to reduce external electromagnetic interference; 2500Vrms optical isolation between the serial port and the host, completely cutting off the ground loop, avoiding communication failures caused by potential difference; suitable for industrial sites with strong interference such as frequency converters, motors, and high-voltage equipment.

Wide Temperature Operation, Stable in Extreme Environments

Operating temperature covers -20℃ to +60℃, can work stably in extremely environments such as refrigerated warehouses, beside high-temperature furnaces, and outdoor exposure; Reinforced PCB board and components, strong anti-vibration and anti-impact ability, suitable for vibration scenarios such as machine tools and production lines.

VIII. Interface Definition and Wiring Specifications

DB9 Serial Port Pin Definitions (RS-232/422/485 Reuse)

Pin 1: DCD (Data Carrier Detect, RS-232);

Pin 2: RXD (Receive Data, RS-232/422/485);

Pin 3: TXD (Transmit Data, RS-232/422/485);

Pin 4: DTR (Data Terminal Ready, RS-232);

Pin 5: GND (Signal Ground);

Pin 6: DSR (Data Set Ready, RS-232);

Pin 7: RTS (Request to Send, RS-232/422/485);

Pin 8: CTS (Clear to Send, RS-232/422/485);

Pin 9: RI (Ring Indicator, RS-232). 

RS-485 Wiring: Pin 7 (RTS+), Pin 8 (CTS-), Pin 5 (GND); RS-422 Wiring: Pin 2 (RXD+), Pin 3 (TXD+), Pin 7 (RTS+), Pin 8 (CTS-), Pin 5 (GND).

Wiring Specifications

Cable: RS-232 uses shielded twisted pair (3 cores), RS-422/485 uses shielded twisted pair (2 pairs);

Shielding Layer: Single-ended grounding (terminal side), to avoid ground loop interference;

Terminal Resistance: At both ends of the RS-485 network, a 120Ω terminal resistor needs to be connected (between pin 7 and pin 8), to reduce signal reflection.

VII. Typical Application Scenarios

XYCOM Industrial Terminal Expands Modbus Interface

To add an independent Modbus serial port to XYCOM 4153B/4153C and other HMI devices, while connecting PLC (RS-485) and serial printers (RS-232), to achieve integrated data monitoring, equipment control, and report printing, without the need for additional gateways, reducing costs.

Upgrade of Old Industrial Systems, Protocol Conversion

For ** legacy system upgrade **, connect XYCOM terminals to modern Modbus networks to achieve data communication with new PLCs and DCS; support Modbus and ASCII protocol conversion, suitable for compatible scenarios of old instruments and new equipment.

Multi-device Network Monitoring, Data Collection

In production lines, chemical industries, energy, etc., connect 32 or fewer instruments, frequency converters, sensors through RS-485 networking, and the XYCOM terminal collects data from all devices through 4800-E7, achieving centralized monitoring, fault alarms, and data traceability.

Data Communication in Hazardous Areas

Combined with XYCOM 4153C (Class I Division 2 certification), in flammable and explosive environments such as oil, gas, and pharmaceutical industries, through 4800-E7, realize safe data communication between on-site equipment and terminals, meeting explosion-proof requirements.

VIII. Installation and Configuration Key Points Installation steps

During power outage, open the XYCOM terminal case and locate the idle ISA slot;

Insert the 4800-E7 card vertically into the ISA slot, ensuring that the gold fingers are fully in contact;

Close the case, connect the DB9 serial cable to the field device (PLC / instrument);

Power on and start the system. The system will automatically recognize the new hardware (DOS/Windows do not require drivers).

Configuration steps

DOS system: Run the 4800-E7 configuration tool, set the serial port parameters (baud rate / parity bit), Modbus address, master-slave station mode;

Windows system: Install the driver, then configure the serial port parameters in the device manager, and set the Modbus communication parameters through the configuration software (Intouch/Fix);

Cable inspection: Confirm that the RS-485 terminal resistor is connected correctly, the shield layer is single-ended grounded, and the cable is undamaged.

IX. Comparison with similar products

4800-E7: ISA bus + Modbus RTU/ASCII + optocoupling + wide temperature range, designed specifically for the XYCOM 4000 series, plug-and-play, compatible with legacy systems;

General Modbus serial card: mostly PCI bus, does not support ISA slot, cannot be adapted to the XYCOM 4153B/4153C and other old terminals;

Modbus gateway: requires additional power supply, wiring, high cost, occupies space, 4800-E7 is directly inserted into the terminal, no additional equipment required.

X. Troubleshooting guide

Power indicator does not light up (PWR light off)

Check if the ISA slot is tightened and the gold fingers are oxidized (clean with an eraser);

Confirm that the +5V DC power supply of the host is normal, and test with a different ISA slot;

Card body damage, contact after-sales for repair.

TX/RX indicator does not flash, no communication

Check if the serial port wiring is correct (no reverse connection of RS-485 positive and negative lines), and if the terminal resistor is connected;

Confirm that the serial port parameters (baud rate / parity bit) are completely consistent with the slave station equipment;

Replace the serial port cable and DB9 interface, and check for cable faults.

Unstable communication, data packet loss

Check if the shield layer is single-ended grounded, and if there is strong electromagnetic interference (away from frequency converters / motors);

Reduce the baud rate (e.g. from 115200 to 9600), reduce signal interference;

Check if the terminal resistor is 120Ω and the number of network nodes does not exceed 32.

ERR indicator constantly lit (fault alarm)

Check if the serial port is short-circuited, or if the wiring is incorrect causing overcurrent;

Card body communication chip damaged, replace the expansion card for testing.


加入收藏
Previous:XYCOM 4153C (PM4153C) Industri
Next:XYCOM 4810E Industrial Communi
返回列表

随便看看

  • XYCOM 4800-E7 (Modbus Protocol Expansion Card) Product Description
  • XYCOM 70113-001 Industrial VME Bus Module - Detailed Product Description
  • XYCOM 4810ER Industrial Multi-Serial Port Communication Card Detailed Product Description
  • XYCOM 4153C (PM4153C) Industrial Touch Operating Terminal (HMI)
  • XYCOM 70100-001 XVME-101 Industrial VME Bus Memory Module - Detailed Product Description
  • XYCOM 4810-KYB Industrial Keyboard Module - Detailed Product Description
  • XYCOM 5012-KPM Industrial Workstation Detailed Product Description
  • XYCOM 5015T-24V Industrial Touchscreen Workstation Detailed Product Description
  • XYCOM 4860A Industrial Operator Terminal Detailed Product Description
  • XYCOM 4810E Industrial Communication Interface Card - Detailed Product Description

产品推荐

Our company specializes in the global supply of industrial automation spare parts and components from leading international brands. We focus on modules and spare parts for DCS systems, robotic systems...

Quick Links

  • About us
  • Product
  • Case
  • News
  • Contact Us

Contact Us

Phone

+86 18705930789

Email

574887443@qq.com
WhatsApp QR code

WhatsApp

Scan the QR code
WeChat QR code

WeChat

Scan the QR code
Copyright © Ningde Androld Automation Equipment Co.,Ltd.
WhatsApp QR code preview
WeChat QR code preview