Product Overview The AM164 is a compact, high-performance industrial combined sounder and beacon manufactured by E2S UK, designed for general industrial, fire safety, commercial and marine emergency warning systems. As a cost-effective mainstream model in the E2S conventional alarm series, the AM164 integrates a high-output electronic sounder and high-brightness xenon strobe light source, delivering stable dual audible and visual emergency warnings. Featuring lightweight compact structure, low power consumption, wide voltage adaptability and IP65 high ingress protection, the unit supports multi-tone programmable output and multi-device synchronous operation. It is fully optimized for long-term stable operation in indoor and outdoor conventional industrial environments, widely adopted in global fire protection, factory safety, municipal infrastructure and general industrial alarm projects.

Description

AM164 Industrial Sounder Beacon Full Product Specification

AM164.jpg

1. Product Overview

The AM164 is a compact, high-performance industrial combined sounder and beacon manufactured by E2S UK, designed for general industrial, fire safety, commercial and marine emergency warning systems. As a cost-effective mainstream model in the E2S conventional alarm series, the AM164 integrates a high-output electronic sounder and high-brightness xenon strobe light source, delivering stable dual audible and visual emergency warnings.
Featuring lightweight compact structure, low power consumption, wide voltage adaptability and IP65 high ingress protection, the unit supports multi-tone programmable output and multi-device synchronous operation. It is fully optimized for long-term stable operation in indoor and outdoor conventional industrial environments, widely adopted in global fire protection, factory safety, municipal infrastructure and general industrial alarm projects.

2. Product Characteristics

The AM164 is a standard xenon strobe sounder beacon without halogen rotating lamp version. The high-intensity xenon flash provides outstanding long-distance visibility and strong visual identification in dark, smoky and high-bright ambient environments. The built-in high-efficiency sounder ensures clear audible warning coverage even in noisy industrial sites.
This model covers mainstream industrial and fire system voltage specifications, including DC24V, DC48V, AC115V and AC230V, perfectly compatible with conventional fire alarm control panels and industrial power supply systems worldwide.

3. Core Technical Specifications

3.1 Audible Performance Parameters

  • Maximum Sound Pressure Level: 104dB(A) @ 1 metre

  • Programmable Tones: 64 built-in international standard industrial and fire alarm tones

  • Industry Compliance: Conforms to PFEER, UKOOA, DIN and global fire safety tone specifications

  • Alarm Stages: Support multi-stage graded alarm for warning, fault and emergency modes

  • Volume Adjustment: Stepless volume tuning adapts to different ambient noise levels

  • Synchronous Operation: Automatic synchronous sounding for multiple networked units

3.2 Visual Performance Parameters

  • Light Source Type: High-power industrial xenon strobe tube

  • Flash Mode: Standard emergency constant flash frequency for industrial alarm

  • Visual Performance: High luminous intensity with excellent penetration against dust, smoke and strong ambient light

  • Lens Color Options: Red, Amber, Green, Blue, Clear for different hazard classification

  • Service Reliability: Stable intermittent flash output, long operational lifespan for continuous duty

3.3 Electrical Specifications

The AM164 supports multiple universal voltage versions to match global fire and industrial control systems, with stable power consumption and complete anti-interference protection:
  • DC24V Version: Operating voltage 18–30Vdc, low standby power, standard for fire alarm systems

  • DC48V Version: Operating voltage 40–56Vdc, suitable for long-distance loop power supply

  • AC115V / AC230V Version: Industrial AC power supply, independent drive circuit for stable operation

  • Circuit Protection: Built-in reverse polarity protection, over-current and surge protection to prevent wiring errors and grid fluctuation damage

  • Operation Mode: Support continuous and intermittent alarm output modes

3.4 Environmental & Structural Parameters

  • Ingress Protection: IP65, dust-tight and water-resistant, suitable for indoor and outdoor all-weather deployment

  • Housing Material: High-strength flame-retardant engineering plastic, UV-stabilized, anti-aging and corrosion-proof

  • Lens Material: High-transmittance impact-resistant polycarbonate (PC)

  • Operating Temperature: -40℃ to +70℃

  • Storage Temperature: -45℃ to +75℃

  • Working Humidity: 95% RH non-condensing

  • Cable Entry: Standard sealed cable gland for reliable waterproof wiring

  • Weight & Structure: Lightweight integrated compact design, easy handling and installation


  • AM164(2.jpg

4. Main Product Features

4.1 Dual Audible & Visual Warning

The AM164 supports three working modes: sound-only alarm, light-only warning and synchronized sound-light linkage alarm. The high-decibel sounder ensures long-distance auditory recognition, while the high-brightness xenon strobe provides highly distinguishable visual alert, realizing full-dimensional emergency warning for complex industrial and building environments.

4.2 Rich Programmable Alarm Logic

Equipped with 64 built-in international standard alarm tones, the unit can be configured with multi-level alarm logic for early warning, equipment failure and emergency danger. It meets hierarchical safety management standards and supports system linkage output for accurate hazard differentiation.

4.3 Multi-Unit Synchronous Operation

Multiple AM164 devices installed in the same system can achieve synchronous flashing and synchronous sounding, ensuring unified and consistent alarm signals in large workshops, industrial parks and building groups, effectively improving emergency response efficiency and avoiding disordered warning prompts.

4.4 Industrial Grade Durability

With IP65 waterproof and dustproof capability, wide temperature tolerance and anti-corrosion housing, the AM164 operates stably under harsh conditions including wind, rain, high temperature, low temperature and high humidity. Multiple built-in circuit protection mechanisms enhance long-term unattended operation stability and service life.

4.5 Convenient Installation & Low Maintenance

The compact integrated structure supports wall mounting and bracket mounting. Standard wiring terminals and simple internal configuration enable fast on-site installation, commissioning and replacement. The durable xenon light source requires no frequent maintenance, greatly reducing operational and maintenance costs.

5. Certification & Compliance

The AM164 complies with international industrial and fire safety standards, holding CE, UKCA and EAC certifications. It meets PFEER, UKOOA, IMO and other industry specifications, qualifying for global industrial, commercial building, marine and general petrochemical safety projects.

6. Typical Application Scenarios

  • Fire Alarm Systems: Commercial building fire emergency alert, smoke and heat detection linkage warning

  • General Industrial Sites: Workshop equipment fault alarm, production line abnormal status prompt

  • Chemical & Energy Facilities: Non-hazardous area gas leakage warning and safety evacuation prompting

  • Marine & Offshore Auxiliary Areas: Cabin and platform public area emergency alarm

  • Public Infrastructure: Power stations, pumping stations, rail transit and municipal engineering emergency warning

7. Installation & Maintenance Guidelines

7.1 Installation Instructions

Install the unit in open and unobstructed positions to guarantee optimal sound propagation and light visibility. Avoid installation in long-term corrosive and heavy dust accumulation areas. Standardize wiring according to corresponding voltage specifications; fully seal cable inlets for outdoor installation to prevent water and dust ingress. Unify device configuration parameters for multi-unit linkage systems to ensure synchronous alarm performance.

7.2 Daily Maintenance

Regularly clean dust and stains on the lens and housing to maintain light transmittance and sound output effect. Periodically inspect wiring tightness and cable aging conditions. The xenon light source features stable performance and low failure rate without frequent replacement. Keep the device surface clean and unobstructed to sustain optimal warning performance throughout operation.

AM164(3.jpg

8. Product Advantages

  • Balanced Warning Performance: 104dB high sound pressure plus high-intensity xenon strobe, adapting to most general industrial emergency scenarios

  • Wide Compatibility: Full mainstream voltage options, compatible with global fire and industrial control systems

  • Flexible Programmability: 64 standard tones and multi-stage alarm modes to meet diverse industry standard requirements

  • Rugged Environmental Adaptability: IP65 protection grade and wide temperature range for indoor and outdoor harsh environments

  • Cost-Effective Operation: Simple structure, easy installation and maintenance, stable long-term operation

  • Global Standard Compliance: Multiple international certifications, applicable for global engineering bidding and delivery


Get a Quote