The AL132 is a compact, high-performance industrial xenon sounder beacon developed by E2S UK, belonging to the upgraded AL100 product series. It is an all-in-one combined audible and visual alarm unit designed for universal emergency warning applications, covering industrial plants, fire safety systems, marine facilities, commercial buildings and outdoor harsh environment sites. Integrated with a high-efficiency electronic sounder and high-intensity xenon strobe lamp, the AL132 delivers powerful dual audible and visual warning signals. Adopting low-power circuit design and rugged industrial structure, the unit supports programmable multi-tone output, multi-stage alarm logic and synchronous group operation. With excellent environmental adaptability and reliable long-term operation performance, it serves as a standard safety alarm device for global industrial and fire protection projects.

Description

AL132.jpg

1. Product Overview

The AL132 is a compact, high-performance industrial xenon sounder beacon developed by E2S UK, belonging to the upgraded AL100 product series. It is an all-in-one combined audible and visual alarm unit designed for universal emergency warning applications, covering industrial plants, fire safety systems, marine facilities, commercial buildings and outdoor harsh environment sites.
Integrated with a high-efficiency electronic sounder and high-intensity xenon strobe lamp, the AL132 delivers powerful dual audible and visual warning signals. Adopting low-power circuit design and rugged industrial structure, the unit supports programmable multi-tone output, multi-stage alarm logic and synchronous group operation. With excellent environmental adaptability and reliable long-term operation performance, it serves as a standard safety alarm device for global industrial and fire protection projects.

2. Product Model Features

The AL132 series is a dedicated xenon strobe sounder beacon with no halogen rotating version. All configurations are equipped with high-brightness xenon flash light source, providing outstanding long-distance visibility and strong visual impact for emergency scenarios. It is widely used for fire alarm, toxic and flammable gas leakage warning, mechanical equipment fault alert, emergency stop indication and on-site personnel evacuation prompting.

The series supports full industrial voltage specifications: DC24V, DC48V, AC24V, AC48V, AC115V, AC230V, which are compatible with most global industrial control systems and fire alarm power supply standards.

AL132(2.jpg

3. Core Technical Specifications

3.1 Audible Performance Parameters

  • Maximum Sound Pressure Level: 112dB(A) @ 1 metre

  • Adjustable Tones: 64 programmable industrial standard tones

  • Industry Compliance: Compatible with PFEER, UKOOA, DIN and international fire alarm tone standards

  • Alarm Levels: Multi-stage graded alarm output, supporting custom warning, fault and emergency alarm modes

  • Volume Control: Stepless volume adjustment available for different ambient noise environments

  • Synchronous Operation: Multiple AL132 units can be synchronized for unified alarm output in large-area systems

3.2 Visual Performance Parameters

  • Light Source Type: High-intensity xenon strobe tube

  • Flash Frequency: Standard industrial emergency flash rate

  • Luminous Intensity: High brightness with excellent penetration for smoky, dusty and outdoor strong-light environments

  • Lens Color Options: Red, Amber, Green, Blue, Clear for different hazard level identification

  • Working Life: Stable xenon flash output with long service life under continuous intermittent operation

3.3 Electrical Specifications

The AL132 provides comprehensive AC and DC voltage versions to meet global industrial and fire system requirements, with stable power consumption and strong anti-interference capability:
  • DC24V Version: Operating voltage range 18–30Vdc, low standby power consumption

  • DC48V Version: Operating voltage range 40–56Vdc, suitable for industrial long-distance loop power supply

  • AC24V / AC48V Version: Low-voltage AC safety power supply for building fire systems

  • AC115V / AC230V Version: High-voltage AC industrial power supply, independent power drive design

  • Circuit Protection: Built-in reverse polarity protection, over-current and surge protection to prevent wiring and grid fluctuation damage

3.4 Environmental & Structural Parameters

  • Ingress Protection Rating: IP65, fully dust-tight and waterproof, suitable for indoor and outdoor all-weather use

  • Housing Material: High-strength flame-retardant engineering plastic, UV-stabilized, anti-aging and corrosion-resistant

  • Lens Material: High-transmittance polycarbonate (PC), impact-resistant and durable

  • Operating Temperature: -40℃ to +70℃

  • Storage Temperature: -45℃ to +75℃

  • Working Humidity: 95% RH non-condensing

  • Cable Entry: Standard sealed cable gland, convenient and reliable wiring

  • Structure Feature: Compact integrated design, lightweight and easy for installation

  • AL132(3.jpg

4. Main Product Features

4.1 Dual Audible & Visual Emergency Warning

The AL132 supports independent sound-only alarm, light-only warning and synchronized sound-light linkage alarm. The high-decibel sounder ensures long-distance auditory recognition, while the xenon strobe provides high-visibility visual warning, achieving all-dimensional emergency prompting effect for complex industrial environments.

4.2 Programmable Multi-Stage Alarm Logic

Equipped with 64 built-in international standard alarm tones, the device can be configured with different alarm levels for early warning, equipment failure and emergency danger. It supports system linkage and graded alarm output, which can accurately distinguish hazard levels and meet hierarchical safety management requirements.

4.3 Synchronous Group Operation Function

Multiple AL132 devices installed in the same system can realize synchronous flashing and synchronous sounding, ensuring consistent alarm signals in large workshops, factory zones and building groups, avoiding disordered warning signals and improving emergency response efficiency.

4.4 Rugged Industrial Grade Reliability

With IP65 waterproof and dustproof grade, wide temperature working range and anti-corrosion housing, the AL132 can work stably in outdoor wind, rain, high temperature, low temperature and high humidity environments. The built-in multiple circuit protection designs effectively improve the stability and service life of long-term unattended operation.

4.5 Flexible & Simple Installation

The compact integrated structure supports wall mounting and bracket mounting. The standard wiring interface and pluggable circuit design make on-site installation, wiring and replacement convenient and fast, reducing construction and maintenance costs.

5. Certification & Compliance Standards

The AL132 series complies with a full range of international industrial and fire safety standards, holding CE, UKCA and EAC certifications. It meets PFEER, UKOOA, IMO and other industry specifications, and is qualified for global industrial, marine, petrochemical and commercial building fire safety projects.

6. Typical Application Scenarios

  • Fire Safety System: Building fire emergency alarm, smoke and heat detection linkage warning

  • Chemical & Energy Industry: Flammable and toxic gas leakage alarm, high-risk area safety alert

  • Industrial Manufacturing: Production line equipment failure, emergency stop and abnormal state warning

  • Marine & Offshore: Platform and cabin emergency alarm and personnel evacuation prompting

  • Public Infrastructure: Power stations, pumping stations, rail transit and municipal engineering emergency warning


  • AL132(4.jpg

7. Installation & Maintenance Guidelines

7.1 Installation Instructions

Install the device in an open position without shelter to ensure sound transmission and light visibility. Avoid long-term exposure to strong corrosive gas and heavy dust accumulation areas. Standardize wiring according to voltage specifications, ensure reliable sealing of cable inlets for outdoor installation, and prevent water and dust ingress. For multi-device linkage systems, unify configuration parameters to guarantee synchronous alarm performance.

7.2 Daily Maintenance

Regularly clean the lens and housing surface to ensure light transmission and sound output effect. Periodically check wiring tightness and cable aging condition. The xenon light source is durable with low failure rate, and no frequent replacement is required. Keep the equipment surface clean and unobstructed to maintain optimal warning performance all year round.

8. Product Advantages

  • Excellent Warning Performance: High sound pressure level plus high-intensity xenon strobe, suitable for long-distance and complex environment emergency warning

  • Powerful Compatibility: Full voltage range versions available, compatible with global fire and industrial control systems

  • Rich Programmable Functions: 64 standard tones and multi-stage alarm modes to meet diverse industry standard requirements

  • Superior Environmental Adaptability: IP65 high protection grade and wide temperature working range for harsh industrial conditions

  • Low Operation & Maintenance Cost: Compact structure, easy installation and stable performance, reducing long-term maintenance investment

  • Global Standard Compliance: Multiple international certifications, applicable for global engineering bidding and project delivery