PROSOFT 5202-DFNT-MCM4 18-32VDC Protocol Gateway Description
November 25, 2026

PROSOFT 5202-DFNT-MCM4 18-32VDC Protocol Gateway Description

ProSoft 5202-DFNT-MCM4 18-32VDC protocol gateway for EtherNet/IP and Modbus protocol conversion and data mapping

Description

PROSOFT 5202-DFNT-MCM4 18-32VDC Protocol Gateway Description

Overview

The PROSOFT 5202-DFNT-MCM4 18-32VDC is an independent protocol gateway from the ProLinx series for industrial network integration. This protocol gateway establishes bidirectional data exchange between EtherNet/IP network and Modbus serial devices, and the protocol gateway carries four configurable serial ports for connecting multiple Modbus RTU or ASCII master and slave instruments. It adopts DIN rail mounting and works as a standalone bridge without relying on PLC backplane, convenient for on-site retrofit and system upgrade.

Features

The PROSOFT 5202-DFNT-MCM4 18-32VDC provides flexible protocol conversion between EtherNet/IP explicit messaging and Modbus serial protocol. The protocol conversion allows each serial port to be set independently as master or slave, and the protocol conversion supports large register mapping for process data collection and control command forwarding. It has built-in web page configuration and diagnostic function, and supports ProSoft discovery service for IP setting and firmware upgrade. Front status LEDs show Ethernet, serial channel and fault alarm information. The module supports data mapping table configuration and communication log storage for troubleshooting, and it isolates different network segments to avoid cross-interference.

Technical Parameters

The PROSOFT 5202-DFNT-MCM4 18-32VDC accepts DC power input within 18V to 32V. It is equipped with one 10/100Mbps Ethernet port and four RS232/RS485 serial ports. The working temperature ranges from -25℃ to +70℃, non-condensing humidity 5% to 95%. It supports Modbus RTU, Modbus ASCII and EtherNet/IP protocols, and meets industrial EMC standards for cabinet installation. The maximum mapped register quantity can meet conventional process control data exchange requirements.

Working Principle

EtherNet/IP data from the upper controller is received by the PROSOFT 5202-DFNT-MCM4 18-32VDC and converted into Modbus serial frames to send to field instruments. Modbus feedback signals from field devices are packaged into EtherNet/IP messages and uploaded back to the host system. The whole interconnection process relies on stable data mapping, and the data mapping defines the corresponding relation between CIP data and Modbus registers. Accurate data mapping realizes seamless integration of new EtherNet/IP control platform and legacy Modbus equipment.

Application Fields

The PROSOFT 5202-DFNT-MCM4 18-32VDC is widely used in petrochemical, power, water treatment and factory automation industries. It is applied to connect Modbus transmitters, valves and meters to Allen-Bradley Logix series EtherNet/IP control systems.