MOOG D661-5611 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
5611 = Spool/sleeve assembly; rated flow 75 L/min @ ΔP=35 bar (high‑response, linear trim)
Typical full config example: G075HAAM6NSX2‑11
G075 = 75 L/min rated flow & high frequency response
HAAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
6 = 6+PE connector, IP65
NSX2 = NBR seals, wide temp range, LVDT 4–20 mA feedback
11 = High‑response ServoJet® pilot stage
Technical Specifications
Hydraulic Parameters
Rated flow: 75 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 8–10 ms (0→100%, 210 bar)
Hysteresis: <0.10%
Resolution: <0.05%
Null drift: <1.5% (ΔT=55 K)
Null leakage: <14 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)Moog Inc.
Connector: 6+PE, IP65Moog Inc.
Current draw: ≤750 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 5.5 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mAMoog Inc.
Feedback: 4–20 mA (spool position)Moog Inc.
Status: Fault alarm output
Core Functions
High‑Response ServoJet® Pilot: Optimized for 75 L/min, fast step response, excellent dirt tolerance
Integrated PID Amplifier: Onboard dead‑zone compensation, thermal/overload protection, stable null
LVDT Closed‑Loop Feedback: High linearity and repeatability for precision motion control
Fail‑Safe Centering: Spool returns to neutral on power loss
75 L/min Balanced Flow‑Dynamics: Tuned for medium‑sized systems needing speed and accuracy
Application Scenarios
Industrial automation: Precision CNC machines, medium hydraulic presses, injection molding equipment
Test equipment: Structural fatigue testers, vibration tables, actuator test benches
Metallurgy: Tension control, light‑duty AGC roll gap control
Energy: Wind turbine pitch control, marine auxiliary hydraulics
Usage & Maintenance
Installation: Horizontal/vertical mounting; minimize vibration
Fluid: ISO VG46 mineral oil; maintain NAS 1638 Class 6 cleanliness
Commissioning: Apply 24 VDC; connect ±10 V/±10 mA command; calibrate zero/gain via 4–20 mA feedback
Maintenance: Check contamination every 3 months; calibrate every 6 months; avoid long idle periods at high pressure
Get a Quote