MOOG D661-5009 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
5009 = Spool/sleeve assembly; rated flow 250 L/min @ ΔP=35 bar (max‑flow, high‑response, contamination‑resistant trim)
Typical full config example: P250HAAM7NSX2‑J
P250 = 250 L/min rated flow & high frequency response
HAAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
7 = 7+PE connector, IP65
NSX2 = NBR seals, wide temp range, LVDT 4–20 mA feedback
J = High‑response ServoJet® pilot stage with enhanced dirt tolerance
Technical Specifications
Hydraulic Parameters
Rated flow: 250 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 15–18 ms (0→100%, 210 bar)
Hysteresis: <0.20%
Resolution: <0.10%
Null drift: <2.0% (ΔT=55 K)
Null leakage: <32 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 7+PE, IP65
Current draw: ≤1050 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 12.0 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
High‑Response, Dirt‑Tolerant ServoJet® Pilot: Optimized for 250 L/min, faster step response, robust to contamination
Integrated PID Amplifier: Onboard dead‑zone compensation, thermal/overload protection, stable null at high flow
LVDT Closed‑Loop Feedback: Reliable linearity and repeatability for demanding motion control
Fail‑Safe Centering: Spool returns to neutral on power loss
250 L/min High‑Flow Dynamics: Tuned for large hydraulic systems needing both high flow and fast response
Application Scenarios
Metallurgy: High‑speed AGC roll gap control, dynamic tension control in heavy mills
Test equipment: High‑speed structural fatigue testers, multi‑axis vibration tables, heavy actuator test benches
Industrial automation: Large high‑speed CNC machines, 1000‑ton+ hydraulic presses, large injection molding machines
Energy & heavy industry: Wind turbine pitch control, marine main hydraulics, steel mill main drive control
Usage & Maintenance
Installation: Horizontal/vertical mounting; minimize vibration/shock
Fluid: ISO VG46 mineral oil; maintain NAS 1638 Class 6 cleanliness
Commissioning: Apply 24 VDC; connect ±10 V/±10 mA command; calibrate zero/gain via 4–20 mA feedback
Maintenance: Check fluid contamination every 3 months; calibrate zero/gain every 6 months; avoid long idle periods at high pressure
Get a Quote