MOOG D661-5000 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
5000 = Spool/sleeve assembly; rated flow 250 L/min @ ΔP=35 bar (max‑flow, high‑response trim)
Typical full config example: P250HAAM7NSX2‑E
P250 = 250 L/min rated flow & high frequency response
HAAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
7 = 7+PE connector, IP65
NSX2 = NBR seals, wide temp range, LVDT 4–20 mA feedback
E = Max‑flow ServoJet® pilot stage
Technical Specifications
Hydraulic Parameters
Rated flow: 250 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)
Step response: 15–18 ms (0→100%, 210 bar)
Hysteresis: <0.20%
Resolution: <0.10%
Null drift: <2.0% (ΔT=55 K)
Null leakage: <32 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)
Control signal: ±10 V (differential) or ±10 mA
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 7+PE, IP65
Current draw: ≤950 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 11.2 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
Max‑Flow ServoJet® Pilot: Optimized for 250 L/min, fast dynamics, robust contamination tolerance
Integrated Digital Amplifier: Onboard PID, dead‑zone compensation, thermal & overload protection
LVDT Closed‑Loop Feedback: Excellent linearity and repeatability across full stroke
Fail‑Safe Centering: Spool returns to neutral on power loss
250 L/min Flow Optimization: Highest flow rating in D661 series for large‑scale hydraulic systems
Application Scenarios
Metallurgy: High‑speed AGC roll gap control for heavy plate mills, high‑force tension control
Test equipment: Large‑scale dynamic material fatigue testers, high‑force vibration tables, heavy‑duty actuator test benches
Industrial automation: Large CNC machine tools, high‑tonnage hydraulic presses, large‑format plastic injection molding machines
Energy & heavy industry: Wind turbine pitch control (high power), marine main hydraulic systems, steel mill main drive control
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibration and shock
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6
Commissioning: Apply 24 VDC power; connect ±10 V/±10 mA command; calibrate zero and gain via 4–20 mA feedback
Maintenance: Inspect fluid contamination every 3 months; calibrate zero/gain every 6 months; avoid long idle periods at high pressure
Get a Quote