MOOG D661-4902 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
4902 = Spool/sleeve assembly; rated flow 250 L/min @ ΔP=35 bar (high‑linearity, low‑leakage trim)
Typical full config example: P250HAAM7NSX2‑B
P250 = Max flow & ultra‑high frequency response
HAAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
7 = 7+PE connector, IP65
NSX2 = NBR seals, wide temp range, LVDT 4–20 mA feedback
B = High‑linearity ServoJet® pilot stage
Technical Specifications
Hydraulic Parameters
Rated flow: 250 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 17–21 ms (0→100%, 210 bar)
Hysteresis: <0.18%
Resolution: <0.08%
Null drift: <2.0% (ΔT=55 K)
Null leakage: <30 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15Moog Inc.
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 7+PE, IP65
Current draw: ≤950 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 11.2 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
High‑Linearity ServoJet® Pilot: Better straight‑line flow characteristic, lower distortion
Integrated High‑Response Amplifier: Built‑in PID, dead‑zone compensation, overload protection
LVDT Closed‑Loop Feedback: High linearity and precision across full stroke
Fail‑Safe Centering: Spool returns to neutral on power loss
Max‑Flow Stability: Optimized for 250 L/min with smooth, stable response for large hydraulic systems
Application Scenarios
Metallurgy: High‑precision AGC roll gap control for heavy plate mills, high‑force tension control
Test equipment: Dynamic material testers, large‑scale high‑force vibration tables
Industrial automation: Large CNC machine tools, heavy‑duty hydraulic presses, large blow molding machines
Energy & heavy industry: Wind turbine pitch control (high‑power), marine hydraulic propulsion, steel mill drives
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibration
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6Moog Inc.
Commissioning: Apply 24 VDC power; connect ±10 V/±10 mA command; calibrate zero and gain via 4–20 mA feedback
Maintenance: Inspect fluid contamination regularly; calibrate zero/gain every 6 months; avoid long idle periods at high pressure