MOOG D661-4867 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
4867 = Spool/sleeve assembly; rated flow 220 L/min @ ΔP=35 bar
Typical full config example: P220HAAM7NSX2‑A
P220 = Ultra‑high flow & high frequency response version
HAAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered null
7 = 7+PE connector, IP65
NSX2 = NBR seals, wide temperature range, LVDT feedback 4–20 mA
A = Standard ServoJet® pilot stage
Technical Specifications
Hydraulic Parameters
Rated flow: 220 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 16–20 ms (0→100%, 210 bar)Moog Inc.
Hysteresis: <0.2%
Resolution: <0.1%
Null drift: <2.0% (ΔT=55 K)
Null leakage: <28 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 7+PE, IP65
Current draw: ≤900 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 10.5 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)Moog Inc.
Electrical interface:
Power: 24 VDC, GND, PEMoog Inc.
Command: ±10 V / ±10 mAMoog Inc.
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
ServoJet® pilot stage: Superior contamination resistance, low null drift, extended service lifeMoog Inc.
Integrated high‑response amplifier: Built‑in PID, dead‑zone compensation, overload protectionMoog Inc.
LVDT closed‑loop feedback: High linearity and precision across full strokeMoog Inc.
Fail‑Safe centering: Spool returns to neutral on power lossMoog Inc.
Ultra‑high‑flow dynamics: Optimized for 220 L/min with stable response for extra‑large hydraulic systems
Application Scenarios
Metallurgy: Ultra‑high‑flow AGC roll gap control for ultra‑heavy plate mills, high‑force tension control
Test equipment: High‑precision dynamic material testers, large‑scale high‑force vibration tables
Industrial automation: Extra‑large CNC machine tools, ultra‑heavy‑duty hydraulic presses, large blow molding machines
Energy & heavy industry: Wind turbine pitch control (high‑power), marine main propulsion hydraulic systems, heavy‑duty steel mill hydraulic drives
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibration
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6Moog Inc.
Commissioning: Apply 24 VDC power; connect ±10 V/±10 mA command; calibrate zero and gain via 4–20 mA feedback
Maintenance: Inspect fluid contamination regularly; calibrate zero/gain every 6 months; avoid long idle periods at high pressure