MOOG D661-4691C Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)
4691 = Spool/sleeve assembly; rated flow 250 L/min @ ΔP=35 bar
C = Pressure class; max working pressure 350 bar (P/A/B ports)
Full config (typical: G65JOAA6VSX2HA):
G = ServoJet® pilot stage, standard spool
65 = Frequency response class (≥150 Hz bandwidth)
J = 24 VDC power, ±10 V / ±10 mA analog command
O = Null position: centered (fail‑safe, power‑off centering)
AA = Standard hydraulic/electrical base config
6 = 6+PE connector, IP65
VS = Wide‑temperature sealing
X2HA = LVDT feedback, 4–20 mA output
Technical Specifications
Hydraulic Parameters
Rated flow: 250 L/min (ΔP=35 bar)
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 6–8 ms (0→100%, 210 bar)
Hysteresis: <0.2%
Resolution: <0.1%
Null drift: <1.5% (ΔT=55 K)
Null leakage: <20 mL/min
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)
Connector: 6+PE, IP65Moog Inc.
Current draw: ≤550 mA
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃
Weight: approx. 10.0 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)Moog Inc.
Electrical interface:
Power: 24 VDC, GND, PE
Command: ±10 V / ±10 mA
Feedback: 4–20 mA (spool position)
Status: Fault alarm output
Core Functions
ServoJet® pilot stage: Excellent contamination resistance, low null drift, long service lifeMoog Inc.
Integrated ultra‑high‑response amplifier: Built‑in PID, dead‑zone compensation, overload protection
LVDT closed‑loop feedback: High linearity and precision across full stroke
Fail‑Safe centering: Spool returns to neutral on power lossMoog Inc.
G65 extreme dynamics: ≥150 Hz bandwidth for ultra‑high‑speed industrial applications
Application Scenarios
Metallurgy: Ultra‑high‑flow AGC roll gap control, tension control for heavy plate mills
Test equipment: High‑force dynamic material testers, ultra‑high‑frequency vibration tables
Industrial automation: Large CNC machine tools, high‑speed hydraulic presses, heavy‑duty injection molding machines
Energy & heavy industry: Wind turbine pitch control, shield machine main control, marine hydraulic systems
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibration
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6
Commissioning: Apply 24 VDC power; connect ±10 V/±10 mA command; calibrate zero and gain via 4–20 mA feedback
Maintenance: Inspect fluid contamination regularly; calibrate zero/gain every 6 months; avoid long idle periods at high pressure