MOOG D661-4636 电液伺服阀
Description
Model Explanation (Basic Section)
D661: Series (Integrated Electronics, 24VDC, ISO 4401-05/NG10 Installation) Moog Inc.
4636: Valve Core/Valve Body Assembly and Pilot Stage Specifications (ServoJet® Jet Tube, Standard Flow/Pressure Rating) Moog Inc. Technical Specifications
Hydraulic parameters
Rated flow rate: 75 L/min (ΔP = 35 bar)
Maximum working pressure: 350 bar (P/A/B ports); return oil T port 210 bar (internal leakage) / 350 bar (external leakage) Moog Inc.
Installation standard: ISO 4401-05 (NG10) Moog Inc.
Step response: 6.5–12 ms (0→100%, 210 bar)
Hysteresis: <0.2%; Resolution: <0.1%; Zero drift: ΔT = 55K when **<1.5%**
Electrical parameters
Power supply: 24 VDC (18–32 VDC) Moog Inc.
Control signal: ±10 V or ±10 mA Moog Inc.
Feedback signal: 4–20 mA (valve core position) Moog Inc.
Connection: 6+PE, protection IP65 Moog Inc.
Environment and physics
Working temperature: -40℃ ~ +85℃
Weight: Approximately 5.5 kg
Material: Valve body alloy steel, valve core hard alloy
Interface and communication configuration
Hydraulic interface: P/A/B/T four ports, in accordance with ISO 4401-05 Moog Inc.
Electrical interface:
Power supply: 24VDC, GND, PE
Command: ±10V/±10mA
Feedback: 4–20mA (valve core position)
Status: Valve ready, fault alarm Moog Inc. Core function
ServoJet® Jet Pipe Pre-Controller: Strong anti-contamination performance, low drift, long service life. Moog Inc.
Integrated Closed-loop Amplifier: Built-in PID, hysteresis compensation, overload protection
Valve Core Position Electrical Feedback: High precision and high linearity throughout the full stroke. Moog Inc.
High Dynamic Response: Millisecond response, suitable for high-speed closed-loop control
Low Leakage Design: Zero leakage **< 15 mL/min** Applicable scenarios
Metallurgy: Rolling mill reduction, tension control, AGC system
Test equipment: Material testing machine, vibration table, fatigue test bench
Industrial automation: Precision machine tools, injection molding machines, robots, hydraulic forming machines
Energy and heavy industry: Wind turbine pitch control, shield tunneling machines, ship rudder systems, aircraft ground testing
Use and maintenance
Installation: Horizontal / vertical installation, avoid severe vibration; oil cleanliness NAS 1638-6 grade or better
Commissioning: Power supply 24VDC, connect ±10V/±10mA instructions; observe 4–20mA position feedback, zero adjustment and gain adjustment by Moog Inc.
Maintenance: Regular inspection of oil contamination; calibrate zero point and gain every 6 months; avoid long-term high-pressure standby without instructions