MOOG D661-4627AG75HOA06VSP2HA Electro-hydraulic Servo Valve
Description
Model Explanation
D661: Series code (Integrated electronics, 24VDC, ISO 4401-05 installation)
4627A: Valve core / valve body combination and pilot stage type (ServoJet® jet pipe)
G75: Rated flow rate 75 L/min (ΔP = 35 bar)
H: Maximum working pressure 350 bar (5000 psi)
O: Four-way, critical overlap, linear characteristics
A: ServoJet® jet pipe pilot stage
06: Pilot oil port connection method
V: Fluorine rubber seal (Temperature resistant / Oil resistant)
S: Electrical connector 6+PE (EN175201)
P2: Valve core position feedback 4–20mA Moog Inc.
HA: Standard performance, special option combination Moog Inc. Technical Specifications
Hydraulic parameters
Rated flow rate: 75 L/min (ΔP = 35 bar)
Maximum working pressure: 350 bar (P/A/B ports); return oil T port 210 bar (Moog Inc.)
Installation standard: ISO 4401-05 (NG10)
Step response: 6.5–14 ms (0→100%, 210 bar)
Hysteresis: <0.2%; Resolution: <0.1%
Electrical parameters
Power supply: 24 VDC (18–32 VDC) Moog Inc.
Control signal: ±10 V or ±10 mA Moog Inc.
Feedback signal: 4–20 mA (valve core position)
Connection: 6+PE, protection IP65 Moog Inc.
Environment and physics
Working temperature: -40℃ ~ +85℃
Weight: Approximately 5.5 kg
Material: Valve body alloy steel, valve core hard alloy
Interface and communication configuration
Hydraulic interface: P/A/B/T four ports, in accordance with ISO 4401-05
Electrical interface:
Power supply: 24VDC, GND, PE
Command: ±10V or ±10mA
Feedback: 4–20mA (valve core position)
Status: Valve ready, fault alarm Core function
ServoJet® Jet Pipe Preamplifier: Strong anti-contamination performance, low drift, long lifespan
Integrated closed-loop amplifier: Built-in PID, hysteresis compensation, overload protection
Valve core position electrical feedback: High precision and high linearity throughout the full stroke
High dynamic response: Millisecond-level response, suitable for high-speed closed-loop control
Low leakage design: Zero leakage <15 mL/min Applicable scenarios
Metallurgy: Rolling mill reduction, tension control, AGC system
Test equipment: Material testing machine, vibration table, fatigue test bench
Industrial automation: Precision machine tools, injection molding machines, robots, hydraulic forming machines
Energy and heavy industry: Wind turbine pitch control, shield tunneling machines, ship rudder systems, aircraft ground testing
Use and maintenance
Installation: Horizontal or vertical installation, avoid severe vibration; oil cleanliness NAS 1638-6 grade or better
Commissioning: Power supply 24VDC, connect ±10V/±10mA instructions; observe 4–20mA position feedback, zero adjustment and gain adjustment
Maintenance: Regularly check oil contamination degree; calibrate zero point and gain every 6 months; avoid long-term high-pressure standby without instructions