MOOG D661-4586E Servo‑Proportional Valve
Description
Model Code Explanation (D661-4586E)
D661: Series (ISO 4401‑05 mounting, integrated 24 VDC electronics)
4: 4‑way, zero‑lap, linear flow characteristic
58: Rated flow ≈ 150 L/min (Δp = 35 bar per land)
6: High‑dynamic response, single LVDT feedback, enhanced null stability
E: Command signal = ±10 VDC (differential), non‑explosion‑proof
Technical Specifications
Part Number: D661-4586E
Mounting
Control Function
Hydraulic Parameters
Rated Flow (Δp = 35 bar): 150 L/min (±8%)
Max Operating Pressure (P/A/B): 350 bar (5,000 psi)Moog Inc.
Pilot Pressure (X): 21–280 bar (internal P or external X)
T Port Pressure (Y internal): 210 bar; (Y external): 350 barMoog Inc.
Fluid: Mineral oil (DIN 51524), viscosity 15–45 mm²/s
Temperature: Ambient −20°C to +60°C; Fluid −20°C to +80°C
Weight: Approx. 6.3–6.6 kg
Electrical Parameters
Supply: 24 VDC (18–32 VDC), quiescent 260 mA, dynamic ~580 mAMoog Inc.
Command Signal: ±10 VDC (differential, 10 kΩ impedance)Moog Inc.
Feedback Signal: 4–20 mA (single LVDT spool position, ±0.02% FS accuracy)Moog Inc.
Connector: 6+PE (EN 175201‑804, IP65)Moog Inc.
Step Response (0→100%): 6.5–7.5 ms @ 210 bar (high dynamics for 150 L/min)
Hysteresis: <0.22% (closed‑loop)
Linearity: <±0.28%
Resolution: <0.05%
Interface & Communication Configuration
Electrical: 6+PE connector; 24 VDC power, ±10 V differential command, 4–20 mA LVDT feedbackMoog Inc.
Feedback: Single integrated LVDT (full‑stroke closed‑loop, high accuracy)
Ports: P, A, B, T; optional external X (pilot) and Y (return)
Seal Material: NBR (standard) or FKM (optional, high‑temperature)
Core Functions
150 L/min High Flow: For heavy‑duty, high‑throughput precision hydraulic systems
Enhanced Dynamic Response: 6.5–7.5 ms step response, faster than standard 150 L/min models
±10 V Differential Command: High‑noise‑immunity signal for industrial environments
Premium Closed‑Loop Control: Tight LVDT feedback with ultra‑low hysteresis
ServoJet® Pilot: Jet‑pipe design reduces energy use and improves contamination resistance
Applicable Scenarios
Heavy‑Duty Metal Forming: Large stamping presses, heavy injection molding, forging equipment
High‑Force Dynamic Testing: Aerospace structural testing, high‑capacity vibration tables
Large‑Scale CNC Machinery: Ultra‑precision large machine tools, high‑speed press brakes
Metallurgical Industry: Steel mill rolling mills, continuous casting systems
Compatibility & Installation Notes
Mechanical: Interchangeable with D661 (G/C/D/E), D662/D663 (ISO 4401‑05)
Upgrade: Drop‑in replacement for D661‑4580D when faster response is needed
System Requirements: 24 VDC supply, ±10 V differential analog controller, ISO 4401‑05 manifold
Usage & Maintenance Instructions
Installation: Mount on flat surface (flatness ≤0.02 mm/100 mm; Ra <1 μm) with M6×55/60 bolts (13 Nm, diagonal)
Fluid: ISO VG 32–46, NAS 1638 cleanliness class ≤8
Maintenance: Replace internal filter every 5,000 hours; inspect leaks/connectors periodically
Precautions: Avoid voltage spikes/reverse polarity; do not open standard (E) models in field
Get a Quote