MOOG D661-4580D Servo‑Proportional Valve
Description
Model Code Explanation (D661-4580D)
D661: Series (ISO 4401‑05 mounting, integrated 24 VDC electronics)
4: 4‑way, zero‑lap, linear flow characteristicMoog Inc.
58: Rated flow ≈ 150 L/min (Δp = 35 bar per land)
0: High‑dynamic response, single LVDT feedback, standard null stability
D: Command signal = 2–10 VDC (6 V = null), non‑explosion‑proofMoog Inc.
Technical Specifications
Part Number: D661-4580D
Mounting
Control Function
Hydraulic Parameters
Rated Flow (Δp = 35 bar): 150 L/min (±8%)
Max Operating Pressure (P/A/B): 350 bar (5,000 psi)Moog Inc.
Pilot Pressure (X): 21–280 bar (internal P or external X)Moog Inc.
T Port Pressure (Y internal): 210 bar; (Y external): 350 barMoog Inc.
Fluid: Mineral oil (DIN 51524), viscosity 15–45 mm²/s
Temperature: Ambient −20°C to +60°C; Fluid −20°C to +80°C
Weight: Approx. 6.2–6.5 kg
Electrical Parameters
Supply: 24 VDC (18–32 VDC), quiescent 250 mA, dynamic ~550 mAMoog Inc.
Command Signal: 2–10 VDC (6 V = null, 10 kΩ impedance)Moog Inc.
Feedback Signal: 4–20 mA (single LVDT spool position, ±0.02% FS accuracy)Moog Inc.
Connector: 6+PE (EN 175201‑804, IP65)Moog Inc.
Step Response (0→100%): 7–9 ms @ 210 bar (high dynamics for 150 L/min)Moog Inc.
Hysteresis: <0.25% (closed‑loop)
Linearity: <±0.30%
Resolution: <0.05%
Interface & Communication Configuration
Electrical: 6+PE connector; 24 VDC power, 2–10 V command, 4–20 mA LVDT feedbackMoog Inc.
Feedback: Single integrated LVDT (full‑stroke closed‑loop, high accuracy)Moog Inc.
Ports: P, A, B, T; optional external X (pilot) and Y (return)Moog Inc.
Seal Material: NBR (standard) or FKM (optional, high‑temperature)Moog Inc.
Core Functions
150 L/min High Flow: For high‑throughput precision hydraulic systems
High‑Dynamic Response: 7–9 ms step response, optimized for 150 L/min
2–10 V Command: Industry‑standard single‑ended voltage signal (6 V = center)Moog Inc.
Precision Closed‑Loop Control: LVDT feedback with low hysteresis for accurate positioningMoog Inc.
ServoJet® Pilot: Jet‑pipe design reduces energy use and improves contamination resistanceMoog Inc.
Applicable Scenarios
High‑Flow Precision Forming: Large stamping presses, heavy‑duty injection molding
Dynamic Test Benches: High‑force vibration tables, aerospace structural testing
High‑Performance Machinery: Large CNC machine tools, high‑speed forging equipment
Industrial Automation: Closed‑loop position/velocity control requiring high flow and dynamics
Compatibility & Installation Notes
Mechanical: Interchangeable with D661 (G/C/D), D662/D663 (ISO 4401‑05)Moog Inc.
Upgrade: Drop‑in replacement for lower‑flow D661 models when higher flow is needed
System Requirements: 24 VDC supply, 2–10 V analog controller, ISO 4401‑05 manifoldMoog Inc.
Usage & Maintenance Instructions
Installation: Mount on flat surface (flatness ≤0.02 mm/100 mm; Ra <1 μm) with M6×55/60 bolts (13 Nm, diagonal)Moog Inc.
Fluid: ISO VG 32–46, NAS 1638 cleanliness class ≤8
Maintenance: Replace internal filter every 5,000 hours; inspect leaks/connectors periodically
Precautions: Avoid voltage spikes/reverse polarity; do not open standard (D) models in field