MOOG D661-4573C Servo‑Proportional Valve
Description
Model Code Explanation (D661-4573C)
D661: Series (ISO 4401‑05 mounting, integrated 24 VDC electronics)
4: 4‑way, zero‑lap, linear flow characteristic
57: Rated flow ≈ 100 L/min (Δp = 35 bar per land)
3: Ultra‑high‑dynamic response, single LVDT feedback, maximum null stability
C: Standard performance, non‑explosion‑proof
Technical Specifications
Part Number: D661-4573C
Mounting
Control Function
Hydraulic Parameters
Rated Flow (Δp = 35 bar): 100 L/min (±8%)
Max Operating Pressure (P/A/B): 350 bar (5,000 psi)Moog Inc.
Pilot Pressure (X): 21–280 bar (internal P or external X)Moog Inc.
T Port Pressure (Y internal): 210 bar; (Y external): 350 barMoog Inc.
Fluid: Mineral oil (DIN 51524), viscosity 15–45 mm²/sMoog Inc.
Temperature: Ambient −20°C to +60°C; Fluid −20°C to +80°CMoog Inc.
Weight: Approx. 5.8–6.0 kgMoog Inc.
Electrical Parameters
Supply: 24 VDC (18–32 VDC), quiescent 230 mA, dynamic ~500 mAMoog Inc.
Command Signal: ±10 VDC (differential, 10 kΩ impedance) or 4–20 mAMoog Inc.
Feedback Signal: 4–20 mA (single LVDT spool position, ±0.02% FS accuracy)Moog Inc.
Connector: 6+PE (EN 175201‑804, IP65)Moog Inc.
Step Response (0→100%): 5–6 ms @ 210 bar (ultra‑high dynamics for 100 L/min)Moog Inc.
Hysteresis: <0.15% (closed‑loop)
Linearity: <±0.20%
Resolution: <0.05%
Interface & Communication Configuration
Electrical: 6+PE connector; ±10 V command, 24 VDC power, 4–20 mA LVDT feedbackMoog Inc.
Feedback: Single integrated LVDT (full‑stroke closed‑loop, high accuracy)
Ports: P, A, B, T; optional external X (pilot) and Y (return)Moog Inc.
Seal Material: NBR (standard) or FKM (optional, high‑temperature)Moog Inc.
Core Functions
100 L/min Medium Flow: Balanced flow for precision applications requiring ultra‑fast response
Ultra‑High‑Dynamic Response: 5–6 ms step response, fastest in D661‑4xxx series for 100 L/minMoog Inc.
Maximized Closed‑Loop Control: Tight LVDT feedback with minimal hysteresis for sub‑micron positioning
ServoJet® Pilot: Jet‑pipe design reduces energy use, improves contamination resistance, and lowers null shiftMoog Inc.
Integrated Digital Amplifier: On‑board PID, ramp generator, fault diagnostics, and EMC protection
Applicable Scenarios
Ultra‑Precision Metal Forming: High‑speed fine blanking, ultra‑precision injection molding (sub‑millisecond response critical)
High‑End Test & Simulation: Aerospace vibration tables, high‑frequency fatigue test rigs, automotive component testing (ultra‑high dynamics required)
Precision Machine Tool Hydraulics: Ultra‑precision CNC positioning, high‑speed press brakes, micro‑machining centers
Industrial Automation: Closed‑loop position/velocity control requiring maximum accuracy and fastest settling time
Compatibility & Installation Notes
Mechanical: Interchangeable with D661 (G/C/A), D662/D663 (ISO 4401‑05)Moog Inc.
Upgrade: Drop‑in replacement for D661‑4572C when ultra‑high dynamics are needed
System Requirements: 24 VDC supply, analog controller (±10 V in / 4–20 mA out), ISO 4401‑05 manifoldMoog Inc.
Usage & Maintenance Instructions
Installation: Mount on flat surface (flatness ≤0.02 mm/100 mm; Ra <1 μm) with M6×55/60 bolts (13 Nm, diagonal)Moog Inc.
Fluid: ISO VG 32–46, NAS 1638 cleanliness class ≤8Moog Inc.
Maintenance: Replace internal filter every 5,000 hours; inspect leaks/connectors periodicallyMoog Inc.
Precautions: Avoid voltage spikes/reverse polarity; do not open standard (C) models in field
Get a Quote