May 25, 2026

D634-390C

MOOG D634-390C Direct Drive Servo Valve (DDV) ISO 4401 Size 05 (NG10) – 24 VDC Integrated Electronics Single‑stage pilotless servo valve

Description

MOOG D634-390C

Direct Drive Servo Valve (DDV)

ISO 4401 Size 05 (NG10) – 24 VDC Integrated Electronics
Single‑stage pilotless servo valve

1. Model Definition

  • D634: ISO 4401 Size 05 direct drive servo valve series

  • 390: Maximum flow, highest‑power configuration in D634 range

  • C: Revision C

2. Hydraulic Specifications

  • Mounting: ISO 4401‑05 (NG10)

  • Max working pressure (P/A/B): 350 barMoog Inc.

  • T‑port pressure (no Y): ≤ 50 barMoog Inc.

  • T‑port pressure (with Y): ≤ 350 barMoog Inc.

  • Rated flow (Δp = 35 bar): 300 L/min

  • Peak flow: approx. 400 L/min

  • Internal leakage: ≤ 5.5 L/min

  • Fluid: ISO 11158 mineral oil

  • Fluid temperature: −20 °C ~ +80 °C

  • Fluid cleanliness: ISO 4406 17/14/11

  • Weight: approx. 8.8 kg

3. Dynamic Performance

  • Full‑stroke step response: ≤16 msMoog Inc.

  • −3 dB bandwidth: 65–75 Hz

  • Hysteresis: <0.20% full scale

  • Resolution: <0.10% full scale

  • Null drift (ΔT = 55 K): <1.2% full scale

4. Electrical Specifications

  • Supply: 24 VDC (18–32 VDC)Moog Inc.

  • Max operating current: 4.5 A

  • Standard command: ±10 VMoog Inc.

  • Optional command: ±10 mA / 4–20 mAMoog Inc.

  • Spool position feedback: 0–10 VDC

  • Connector: M18, 6‑pin + PE, IP65Moog Inc.

  • Ambient temperature: −20 °C ~ +60 °C

  • EMC: CE compliant

5. Key Features

  • Pilotless direct drive: Permanent‑magnet linear force motor, no pilot oil required

  • Highest flow rating: Top‑end model for ultra‑high‑flow hydraulic systems

  • Pressure‑independent dynamics: Stable response under varying loads

  • Closed‑loop control: Integrated LVDT for precise spool position feedback

  • Fail‑safe: Spring‑centered, returns to neutral on power loss

  • Integrated electronics: Compact, rugged, PWM‑driven, EMI‑hardened design

6. Typical Applications

  • Heavy‑duty hydraulic presses, forging & extrusion machines

  • Large aerospace/automotive component test rigs

  • High‑force vibration simulators

  • Industrial closed‑loop position, velocity, and pressure control systems

7. Pin Assignment

  1. +24 VDC Power

  2. Power Ground

  3. Command +

  4. Command −

  5. Position Feedback Output

  6. Feedback Ground

    PE: Protective Earth

    Shielded twisted pair recommended for signal wiring.


Get a Quote