D634-362C
Description
1. General Description
2. Model Code (D634‑362C)
D634: Series = Direct drive servo valve, ISO 4401 Size 05 (NG10)Moog Inc.
362: Configuration = ultra‑high‑dynamic, low‑leakage spool, 24 VDC, precision‑tuned
C: Revision C (current production baseline)
3. Hydraulic Specifications
Mounting: ISO 4401 Size 05 (NG10)Moog Inc.
Max Working Pressure (P/A/B): 350 bar (5,000 psi)Moog Inc.
T‑port Pressure (no Y port): 50 bar (725 psi)Moog Inc.
T‑port Pressure (with Y port): 350 bar (5,000 psi)Moog Inc.
Rated Flow (Δp = 35 bar/orifice): 100 L/min (26.4 gpm)
Max Flow: ≈150 L/min
Internal Leakage: ≤2.2 L/min (lowest in D634)
Fluid: Mineral oil (ISO 11158 / DIN 51524)Moog Inc.
Fluid Temp: −20 °C to +80 °C
Fluid Cleanliness: ISO 4406 17/14/11Moog Inc.
Weight: ≈7.0 kg
4. Dynamic Performance (Key Advantage)
Full‑stroke Step Response: ≤16 ms (fastest in D634)
−3 dB Bandwidth: 70–80 Hz (highest in D634)
Hysteresis: <0.15% full scale
Resolution: <0.08% full scale
Null Drift (ΔT = 55 K): <1.0% full scale
5. Electrical Specifications
Supply Voltage: 24 VDC (18–32 VDC)Moog Inc.
Max Operating Current: 2.8 A
Standard Command Signal: ±10 VMoog Inc.
Optional Signals: ±10 mA, 4–20 mAMoog Inc.
Spool Position Feedback: 0–10 VDC (or 4–20 mA)
Connector: M18, 6 pins + PE, IP65Moog Inc.
Ambient Temp: −20 °C to +60 °C
EMC: CE compliant
6. Key Features
Pilotless direct drive: No external pilot supply, simpler installationMoog Inc.
Ultra‑high bandwidth (70–80 Hz): For extreme‑speed closed‑loop systems
Lowest leakage & highest resolution: Precision control for aerospace test stands
Pressure‑independent dynamics: Stable under varying loadsMoog Inc.
Fail‑safe spring return: Protects machinery on power lossMoog Inc.
Integrated PWM electronics: Compact, IP65 protection
7. Typical Applications
Aerospace structural fatigue test rigs (high‑cycle, high‑precision)
High‑speed vibration simulation tables
Precision position/force control for lab & industrial test systems
High‑response hydraulic actuators for robotics & motion simulation
8. Pin Assignment (6+PE)
+24 VDC
Power Ground
Command +
Command –
Position Feedback Out
Feedback Ground
PE: Protective Earth
Use shielded twisted pair for all signal wires.
Get a Quote