D634-1043
Description
1. General Description
No pilot oil required: Permanent magnet linear force motor drives spool directlyMoog Inc..
Spring-centered: Failsafe return to neutral on power lossMoog Inc..
Highest performance in D634 line: max flow + fastest response + highest bandwidth.
Applications: High-speed hydraulic presses, dynamic material test benches, fatigue testing machines, and closed-loop systems requiring ultra-fast response + high flow + minimal leakage.
2. Hydraulic Specifications
Max working pressure (P, A, B): 350 bar (5,000 psi)
T-port pressure: 50 bar (no Y-port); 350 bar (with Y-port)
Rated flow (Δp = 35 bar per land): 100 L/min (26.4 gpm)
Max flow: ~190 L/min (50.2 gpm)
Internal leakage: ≤0.55 L/min
Fluid: Mineral oil per ISO 11158 / DIN 51524
Fluid temperature: −20 °C to +80 °C
Filtration: ISO 4406 17/14/11 or better
3. Performance Characteristics (Key Upgrade vs. 1042)
Step response (0→100% stroke): 9–11 ms (fastest in D634)
−3 dB bandwidth: 115–125 Hz (highest in D634)
Hysteresis: <0.38% FS
Resolution: <0.09% FS
Null drift (60 K change): <0.8% FS
Repeatability: ≤0.22% FS
4. Electrical Specifications
Supply voltage: 24 VDC (range: 18–32 VDC)Moog Inc.
Max operating current: 3.5 A
Command signals (jumper-selectable): ±10 V, ±10 mA, 4–20 mAMoog Inc.
Spool position feedback: 0–10 VDC (standard)
Connector: M18, 6-pin + PE, IP65Moog Inc.
Ambient temperature: −20 °C to +60 °C
EMC: CE compliant
5. Mechanical & Installation
Mounting: ISO 4401 Size 05 (NG10) pattern
Weight: ~6.3 kg (13.9 lb)
Installation: Horizontal mounting recommended; clean surface required; bleed air before commissioning
6. Pinout (M18 Connector)
+24 VDC
Power GND
Command +
Command −
Spool position feedback (0–10 V)
Feedback GND
PE: Protective Earth (chassis ground)
7. Key Differences (vs. 1040/1041/1042)
Flow: 1043 = 100 L/min (same as 1040/1041/1042)
Speed: 1043 = 9–11 ms (fastest; 1042 = 11–13 ms)
Bandwidth: 1043 = 115–125 Hz (highest; 1042 = 105–115 Hz)
Leakage: 1043 = ≤0.55 L/min (same as 1040–1042)
Get a Quote