072A560 is a high-performance hydraulic relief valve. It is mainly applied in various hydraulic systems for pressure setting, system overload protection and pressure releasing. Widely used in construction machinery, lifting equipment, industrial machine tools and mobile hydraulic devices, it can effectively stabilize system working pressure and protect hydraulic components from damage caused by overpressure.

Description

072A560.jpg

1. General Description

072A560 is a high-performance hydraulic relief valve. It is mainly applied in various hydraulic systems for pressure setting, system overload protection and pressure releasing. Widely used in construction machinery, lifting equipment, industrial machine tools and mobile hydraulic devices, it can effectively stabilize system working pressure and protect hydraulic components from damage caused by overpressure.

2. Technical Specifications

Working medium: Mineral based hydraulic oil
Fluid cleanliness: In accordance with ISO 4406 standard
Rated working pressure: 21MPa
Maximum allowable impact pressure: 26MPa
Applicable fluid viscosity: 15-68 mm²/s
Working temperature range: -20℃ ~ +80℃
Adjusting type: Manual stepless pressure regulation
Internal leakage: Low leakage rate
Installation style: Standard fixed installation
Working performance: Support long-term continuous stable operation

3. Main Features

Adopts precision matching spool structure, featuring accurate pressure control and stable pressure maintaining effect. Core components are made of high hardness wear-resistant materials to extend service life. Optimized internal flow channel design lowers flow pressure loss and improves system working efficiency. Superior integral sealing structure effectively prevents external oil leakage. Excellent vibration resistance enables stable operation under various harsh working conditions. Compact structure saves installation space, easy for field installation and replacement. Simple internal structure, low failure rate and convenient daily maintenance and debugging.

4. Installation Guide

Clean the mounting surface and hydraulic oil passages thoroughly to remove sundries, iron scraps and oil dirt before installation. Fix the valve in designated position with standard fasteners and fasten bolts by specified torque, avoid over tightening to prevent body deformation and internal stuck. Connect inlet and return oil pipelines strictly following flow direction marks. Recheck all connecting parts after installation to ensure firm assembly without looseness.

5. Operation Instructions

Perform no-load trial operation after all installation work finished. Inject hydraulic oil slowly and inspect all joints for oil leakage. Adjust the working pressure to required value slowly according to actual working demands. Keep circulating hydraulic oil clean during daily operation, replace system filter elements regularly to avoid internal blockage caused by impurities. It is strictly forbidden to set working pressure beyond the maximum safe limit. Fully release residual pressure inside hydraulic system before equipment shutdown and maintenance work.

6. Daily Maintenance

Check valve body and connecting positions regularly for oil seepage, replace aging sealing parts in time. Periodically check pressure control accuracy and make fine adjustment if pressure deviation appears. Keep outer surface clean to prevent dust and oil stain accumulation affecting heat dissipation and normal use. Unauthorized disassembly is prohibited without professional technical guidance, in case of damaging internal precision parts and affecting control precision.

7. Safety Precautions

All installation, pressure adjustment and maintenance operations must be completed after equipment stop, power cut and full pressure relief of hydraulic system, to avoid personal injury accidents caused by high-pressure hydraulic fluid. Operators must abide by relevant safety operation regulations. Keep the product away from high temperature heat sources and corrosive substances to prevent performance aging and failure. Stop using the product immediately once abnormal noise, overheating and unstable pressure occur during operation, and arrange professional inspection and troubleshooting in time.