MVI56-103M
May 18, 2026

MVI56-103M

Model: MVI56‑103M Manufacturer: ProSoft Technology (Rockwell Automation partner) Platform: Allen‑Bradley ControlLogix (1756 chassis, single‑slot) Protocol: IEC 60870‑5‑103 Master (power system protection/control standard) Function: Enables ControlLogix PLCs to act as an IEC 103 master, communicating with protection relays, substation IEDs, and field devices in electrical substations. Data Exchange: High‑speed backplane data transfer between module and ControlLogix tags; supports telemetry, SOE, fault records, and time synchronization.

Description

MVI56-103M.jpg

1. Product Overview

  • Model: MVI56‑103M

  • Manufacturer: ProSoft Technology (Rockwell Automation partner)

  • Platform: Allen‑Bradley ControlLogix (1756 chassis, single‑slot)

  • Protocol: IEC 60870‑5‑103 Master (power system protection/control standard)

  • Function: Enables ControlLogix PLCs to act as an IEC 103 master, communicating with protection relays, substation IEDs, and field devices in electrical substations.

  • Data Exchange: High‑speed backplane data transfer between module and ControlLogix tags; supports telemetry, SOE, fault records, and time synchronization.

2. Key Features

  • Dual independent master ports (P1, P2), plus CFG debug/config port

  • Port hardware: RS‑232/422/485 (software selectable), electrical isolation

  • Max devices: Up to 32 IEC 103 slaves total across two ports

  • Protocol services:

    • Master polling: Cyclic data acquisition (YX, YC, YM)

    • Event handling: SOE (Sequence of Events), time‑stamped reports

    • Controls: Remote commands, parameter setting

    • File transfer: Fault records, disturbance data

  • RTC & CMOS backup: 21‑day battery backup (non‑replaceable)

  • Diagnostic LEDs: PWR, RUN, BP LINK, P1 ACT, P2 ACT

  • Approvals: CE, UL/cUL, CSA, ATEX, RoHS

3. Technical Specifications

General

  • Slot usage: 1 slot (1756 local/remote rack)

  • Backplane current: 800 mA @ 5 VDC; 3 mA @ 24 VDC

  • Data mapping: Direct tag‑based access (no M0/M1 files)

  • Configuration: ProSoft Configuration Builder (PCB)

Serial Communication (P1/P2)

  • Standards: IEC 60870‑5‑103, RS‑232/422/485

  • Baud rate: 110–115.2 kbps

  • Data bits: 8; Parity: Even/Odd/None; Stop bits: 1/2

  • Connector: RJ45 (P1, P2, CFG)

Environmental

  • Operating temp: 0°C to +60°C (32°F to 140°F)

  • Storage temp: ‑40°C to +85°C

  • Humidity: 5%–95% non‑condensing

  • Vibration: 5 g (10–150 Hz)

  • Shock: 30 g (operational)

4. LED Indicators

  • PWR: On = backplane power OK

  • RUN: On = module operational; flashing = firmware activity

  • BP LINK: On = backplane communication active

  • P1 ACT / P2 ACT: Flashing = data traffic on port 1/2

5. Installation & Configuration

  1. Power off ControlLogix chassis.

  2. Insert MVI56‑103M into empty 1756 slot.

  3. Connect IEC 103 devices to P1/P2; connect PC to CFG port.

  4. Power on; verify module in Studio 5000.

  5. Use ProSoft Configuration Builder (PCB) to define:

    • Port parameters (baud, parity, protocol)

    • Slave addresses (1–32)

    • Data mapping (IEC 103 objects ↔ ControlLogix tags)

  6. Download configuration and test communication.

6. Applications

  • Power substations: Connect ControlLogix to IEC 103 protection relays, breakers, IEDs

  • SCADA integration: Telemetry (YX/YC/YM), SOE, fault data collection

  • Legacy system modernization: Migrate old IEC 103 networks to ControlLogix

  • Distributed power: Wind/solar farm device monitoring

  • Industrial automation: Process control with IEC 103‑compliant devices

7. Advantages

  • Dual‑port master: Two independent networks, flexible topology

  • Power protocol expertise: Full IEC 103 compliance for protection/control

  • Time‑critical data: High‑precision time stamping for SOE/events

  • Robust isolation: Protects against ground loops and EMI in substations

  • Seamless Rockwell integration: Native tag access, no intermediate logic