Model: MVI46‑MBP Manufacturer: ProSoft Technology Platform: Allen‑Bradley SLC 500 (1746 backplane, single‑slot) Protocol: Modbus Plus (MB+), peer‑to‑peer industrial network Function: Enables SLC 500 PLCs to connect to Modbus Plus networks for bidirectional data exchange with Modicon PLCs, drives, relays, power monitors, and other MB+ devices.

Description

MVI46-MBP.jpg

1. Product Overview

  • Model: MVI46‑MBP

  • Manufacturer: ProSoft Technology

  • Platform: Allen‑Bradley SLC 500 (1746 backplane, single‑slot)

  • Protocol: Modbus Plus (MB+), peer‑to‑peer industrial network

  • Function: Enables SLC 500 PLCs to connect to Modbus Plus networks for bidirectional data exchange with Modicon PLCs, drives, relays, power monitors, and other MB+ devices.

2. Key Features

  • Dual‑port Modbus Plus interface (MB+ network, 57.6 kbps, no parity, 1 stop bit)

  • Peer‑to‑peer communication (master/slave supported)

  • 4,000‑word shared data space between SLC and MB+ network via M0/M1 files

  • Up to 100 word read/write per transfer; global in/out: 0–32 words

  • Node address configurable 1–64; supports MB+ routing up to 5 levels

  • Asynchronous data transfer (SLC operations independent of MB+ network)

  • Ladder logic example included for M0/M1 data mapping

  • Diagnostic LEDs: Power, Run, Backplane, MB+ Link/Activity

3. Technical Specifications

General

  • Slot usage: 1 slot (1746 local/extended rack; remote rack not supported)

  • Backplane current: 300 mA @ 5 VDC

  • Data exchange: M0/M1 files (SLC memory access)

Modbus Plus Network

  • Baud rate: 57,600 bps (fixed)

  • Parity/stop bits: No parity, 1 stop bit

  • Max nodes: 64 per network segment

  • Function codes (slave): 1, 2, 3, 4, 5, 6, 15, 16

Environmental

  • Operating temp: 0°C to +60°C (32°F to 140°F)

  • Storage temp: -40°C to +85°C (-40°F to 185°F)

  • Humidity: 5%–95% non‑condensing

  • Vibration: 5 g (10–150 Hz)

  • Shock: 30 g (operational), 50 g (non‑operational)

4. LED Indicators

  • PWR: On = backplane power OK

  • RUN: On = module operational; flashing = firmware activity

  • BP LINK: On = backplane communication active

  • MB+ LINK: On = MB+ network connected

  • MB+ ACT: Flashing = MB+ data transmission

5. Installation & Configuration

  1. Power off the SLC 500 chassis.

  2. Insert MVI46‑MBP into an empty 1746 slot.

  3. Connect MB+ network cable to the module’s MB+ port.

  4. Power on the system; verify module recognition via RSLogix 500.

  5. Configure node address (1–64) and MB+ parameters using the configuration tool.

  6. Map SLC data (M0/M1 files) to MB+ registers via ladder logic.

  7. Download configuration and test MB+ communication.

6. Applications

  • Connect SLC 500 to Modicon PLCs (Modbus Plus)

  • Integrate drives, relays, power monitors into SLC systems

  • Legacy SLC equipment networking upgrades

  • Factory‑wide Modbus Plus network monitoring

  • Industrial SCADA data collection via MB+

7. Advantages

  • Seamless SLC ↔ Modbus Plus integration

  • High‑speed, deterministic MB+ communication

  • Large 4,000‑word data buffer for complex data exchange

  • Robust industrial design for harsh environments

  • Proven compatibility with Rockwell Automation systems