MVI46-DFCM
May 18, 2026

MVI46-DFCM

Model: MVI46-DFCM Manufacturer: ProSoft Technology Applicable System: Allen-Bradley SLC 500 PLC Installation Type: Single slot 1746 in-chassis module Function: This module provides extended DF1 protocol serial communication function for SLC 500 controller. It supports full-duplex and half-duplex working modes, acts as DF1 master or slave station, and realizes data exchange between SLC system and other AB controllers, HMI, SCADA system and third-party DF1 compliant devices.

Description

MVI46-DFCM.jpg

1. Product Overview

Model: MVI46-DFCM
Manufacturer: ProSoft Technology
Applicable System: Allen-Bradley SLC 500 PLC
Installation Type: Single slot 1746 in-chassis module
Function: This module provides extended DF1 protocol serial communication function for SLC 500 controller. It supports full-duplex and half-duplex working modes, acts as DF1 master or slave station, and realizes data exchange between SLC system and other AB controllers, HMI, SCADA system and third-party DF1 compliant devices.

2. Main Features

  1. Fully compliant with standard Rockwell DF1 serial communication protocol

  2. Equipped with two independent isolated serial communication ports

  3. Support RS-232 and RS-485 electrical interface selection

  4. Each port can be independently configured as master station or slave station

  5. Support full-duplex and half-duplex communication modes freely switchable

  6. Built-in large-capacity register database up to 5000 words

  7. Realize data interaction with SLC CPU through M0 and M1 data files

  8. Provide complete ready-made ladder logic program for fast application

  9. Support configuration via ProSoft Configuration Builder software

  10. Independent protocol processing design will not occupy main controller operation resources

3. Technical Specifications

Communication Parameters

Communication Protocol: Allen-Bradley DF1 Protocol
Baud Rate Range: 110bps to 115200bps
Serial Port Settings: 7/8 data bits, none/odd/even parity, 1/2 stop bits
Transmission Mode: Point-to-point, multi-drop and broadcast transmission supported

Power Specification

Power Supply: Powered by 1746 chassis backplane
Operating Current: 800mA at 5VDC

Environmental Performance

Operating Temperature: 0°C ~ +60°C
Storage Temperature: -40°C ~ +85°C
Relative Humidity: 5% ~ 95%, non-condensing
Vibration Resistance: 5g within 10Hz~150Hz frequency range
Impact Resistance: 30g operational impact, 50g non-operational impact

Physical Installation

Mounting Method: Standard single slot installation for 1746 chassis
Application Scope: Suitable for local SLC chassis, not for remote expansion racks

4. LED Status Description

Module Power Light: Indicate backplane power supply status
Run Status Light: Show normal running or fault state of module
Backplane Link Light: Display data communication status between module and SLC CPU
Serial Send Light: Flash when data is transmitted outward
Serial Receive Light: Flash when receiving external DF1 data signal

5. Installation and Configuration Steps

  1. Cut off all power of SLC 500 control system

  2. Insert MVI46-DFCM module into empty slot of 1746 chassis

  3. Connect external DF1 communication equipment to corresponding serial interface

  4. Power on the system and confirm the module is recognized successfully

  5. Set communication mode, station address and serial port parameters via configuration tool

  6. Configure internal data mapping relation according to actual transmission demand

  7. Import matching ladder program to complete data area matching

  8. Download all configurations and user programs to controller

  9. Conduct online communication test to verify data receiving and sending normally

6. Application Scope

  1. Data interconnection between multiple Allen-Bradley PLC equipments

  2. On-site HMI man-machine interface DF1 serial connection communication

  3. Industrial SCADA system remote data collection and monitoring

  4. Transformation and upgrading of old equipment with traditional DF1 communication interface

  5. Factory production line distributed control system data interaction

  6. Building automatic control and mechanical equipment serial signal transmission

7. Product Advantages

  1. Standard DF1 protocol design, excellent compatibility with AB series automation products

  2. Dual-port independent design can build two sets of DF1 communication networks at the same time

  3. Flexible master-slave mode switching meets diverse networking demands

  4. Simple system integration, no complex secondary protocol development required

  5. Stable industrial-grade performance, suitable for long-term continuous field operation

  6. Complete diagnosis function, easy daily maintenance and rapid fault location

8. Safety Operation Notes

  1. All plugging, wiring and maintenance operations must be done under power-off state

  2. Correctly distinguish RS-232 and RS-485 wiring definitions to avoid interface damage

  3. Keep consistent baud rate, parity and station address among all communication devices

  4. Reasonably plan communication address to prevent address conflict and data confusion

  5. Add terminal matching resistance for long-distance RS-485 transmission

  6. Avoid using the module beyond specified temperature and humidity working range