5105-103M-PDPS
Description
1. Product Overview
Part Number: 5105‑103M‑PDPS
Manufacturer: ProSoft Technology (ProLinx 5000 Series)
Product Type: DIN‑rail mounted protocol gateway
Function: Converts Modbus RTU Master (serial) to PROFIBUS DP Slave; enables bidirectional data exchange between Modbus RTU devices and any PROFIBUS DP master (e.g., Siemens PLC).
Protocols:
Serial: Modbus RTU Master
Fieldbus: PROFIBUS DP Slave (PDPS)
2. Key Features
Modbus RTU Master (RS‑232/422/485 configurable)
PROFIBUS DP Slave interface (DB9 female)
Supports Modbus function codes 01, 02, 03, 04, 05, 06, 15, 16
PROFIBUS node address: 0–125 (software configurable)
Baud rates:
Modbus: 1200–115.2 kbps
PROFIBUS: 9.6 kbps–12 Mbps
Data mapping: flexible I/O size, byte/word swapping
Communication fault mode: configurable (hold/freeze/zero)
Isolated serial and PROFIBUS ports
Industrial DIN‑rail mount, compact size
LED status indicators for power, run, serial, PROFIBUS, fault
GSD file included for PROFIBUS configuration tools
Wide temperature range for harsh environments
3. Technical Specifications
3.1 Power
Voltage: 18–32 VDC (24 VDC nominal)
Current: ≤500 mA @ 24 VDC
Power consumption: ≤12 W
3.2 Modbus RTU Master (Serial Port)
Interface: RS‑232 / RS‑422 / RS‑485 (software selectable)
Data bits: 7 / 8
Stop bits: 1 / 2
Parity: None / Even / Odd
Baud rate: 1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k, 115.2k
Modbus: RTU Master, up to 247 slaves
3.3 PROFIBUS DP Slave (PDPS)
Protocol: PROFIBUS DP‑V0/V1 Slave
Node address: 0–125 (software set)
Connector: DB9 female (PROFIBUS standard)
Baud rate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M
Isolation: 2500 Vrms
Process data size: up to 244 bytes IN / 244 bytes OUT
3.4 Environmental
Operating temp: −20 °C to +60 °C
Storage temp: −40 °C to +85 °C
Humidity: 5–95% RH, non‑condensing
Vibration: 5 g, 10–150 Hz
Shock: 30 g (operational)
3.5 Physical
Mounting: standard DIN rail
Dimensions: approx 125 × 80 × 30 mm
Weight: approx 0.45 kg
Certifications: CE, UL/cUL, Class 1 Div 2
4. LED Indicators
PWR: Power ON – steady = OK
RUN: Module operating – flashing = running normally
SER: Modbus serial – flashing = active communication
PBUS: PROFIBUS DP – flashing = data exchange
ERR: Fault – ON = configuration/communication error
5. Installation & Wiring
Mount gateway on DIN rail in cabinet.
Connect 24 VDC power (observe polarity).
Wire Modbus RTU to serial port (RS‑485 recommended for multi‑drop).
Connect PROFIBUS cable to DB9; ensure proper shielding and termination.
Set PROFIBUS address and communication parameters via configuration software.
Configure Modbus RTU Master commands (polling list, function codes, registers).
Download configuration to gateway; verify LED status.
6. Data Mapping
Map Modbus register data to PROFIBUS input/output process data.
Supports:
Coils (bits)
Discrete inputs
Input registers
Holding registers
Byte/word swapping for big‑endian/little‑endian compatibility.
Communication timeout and fault state configurable.
7. Typical Applications
Connect Modbus RTU sensors, meters, drives to Siemens PROFIBUS PLCs
Migrate legacy Modbus devices into PROFIBUS‑based DCS
Factory automation, water treatment, energy management
Retrofit projects mixing Modbus and PROFIBUS networks
8. Safety Notes
Disconnect power before installation/wiring.
Use shielded cables for both serial and PROFIBUS.
Do not exceed voltage and temperature ratings.
Terminate PROFIBUS network at both ends.
Configuration must be performed by qualified personnel.
Get a Quote