8111
May 18, 2026

8111

Core Configuration High-density security system mainframe (core carrier of the system) Slot quantity: 16 I/O/communication module slots Expansion bus: 6 channels of RS-485 I/O expansion ports (A/B/C triple redundancy) System control: 4-bit key switch (RUN/PROGRAM/STOP/LOCK) Supported I/O capacity: Up to 192 digital points / 96 analog points (with high-density module) Backplane rate: I/O bus 375 kbps, communication bus 2 Mbps Electrical parameters System power supply Input voltage: 24VDC ±10% (dual redundant power supply) Power consumption: ≤ 30W (full load of the entire box) Insulation strength: 1500VAC isolation between the back panel and the casing Environment and mechanics Operating temperature: -40℃ ~ +70℃ Humidity: 0%–95% RH (no condensation) Protection level: IP65 (industrial dust and splash protection) Dimensions: 465mm × 578mm × 333mm Weight: Approximately 24.5kg (excluding modules) Product features System Core: Tricon SIS standard chassis, housing CPU, I/O and communication modules Triple Redundancy: TMR hardware architecture, no single point of failure, no system downtime in case of failure High-density Integration: 16-slot design, single chassis covers all point requirements of medium and small-sized SIS Strong Expansion Capability: Supports multi-box cascading (8111/8121 expansion boxes), up to 4096 points Full Self-Diagnosis: Real-time monitoring and reporting of backplane, power supply, bus, and module status Hot Swap Support: All modules can be replaced online without interrupting system operation Wide Temperature Resistance and Anti-Interference: Industrial-grade EMI/EMC protection, suitable for harsh industrial conditions in chemical and power industries Applicable scenarios Chemical / Petrochemical / Oil and Gas: ESD emergency shutdown, BMS burner management, F&G fire protection system core installation carrier TRICONEX 811 Basic Information Model: 8111 Series: Tricon 8100 System Expansion Cabinet Architecture: TMR Triple Module Redundancy Safety Level: SIL3 Compatible System: Compatible with 8110 main cabinet for use Product Status: Widely used in the field, with stable spare parts supply Power/Energy: Boiler protection, turbine interlock, main station cabinet for unit safety control Small and Medium-sized SIS Projects: System deployment completed by a single cabinet, no additional expansion required High-density Safety Control: Compact safety system with concentrated points and limited space Series Differentiation 8110: Standard High-density Main Cabinet (16 slots), system must be equipped 8111: Expansion Cabinet (16 slots), used for I/O point expansion 8121: High-density Expansion Cabinet (32 slots), used for large system expansion 8112: RXM Remote Cabinet, dedicated for remote I/O deployment

Description

Core Configuration

SIS system-specific I/O expansion rack

Standard slots: 16 general-purpose module slots

Bus form: Redundant high-speed I/O expansion bus

Connection method: Dedicated redundant cable connects to the mainframe

Supported modules: Full range of 4500 series I/O modules, 4600 series communication modules Electrical parameters

System power supply: External 24VDC redundant power supply

Stable transmission of bus communication, no signal delay

Equipped with board failure self-check and module in-place detection functions

Industrial standard electrical isolation, effectively suppressing on-site interference Product features

Designed specifically for expanding the Tricon system, seamlessly integrating with the main control cabinet.

Triple redundant bus design, ensuring compliance with SIL3 safety standards even after expansion.

All modules support hot swapping, allowing for maintenance and inspection without affecting the operation of the entire system.

Reasonable internal heat dissipation layout, ensuring stable and reliable operation even during long periods of full-load operation.

Uniform installation structure, with neatly arranged cabinet layout.

Compatible with a full range of safety modules, with flexible and free expansion options. Applicable scenarios

The original host box locations were insufficient, so additional I/O control points were added.

Expansion and setup of the entire SIS system for large-scale chemical, oil and gas, and power projects.

Centralized and unified access of distributed field locations to the safety control system.

Expansion and use of point locations for fire protection and emergency stop systems.

Series differentiation

8110: System main control box

8111: Standard 16-slot expansion box

8121: Large-capacity high-density expansion box

8112: Remote distributed I/O box


Get a Quote