Product Description of ProSoft MVI71-DNP
Description
Product Description of ProSoft MVI71-DNP
MVI71-DNP (DNP 3.0 Master/Slave Communication Module) is a single-slot DNP 3.0 serial communication module specially developed by ProSoft for the Rockwell PLC-5 platform. It supports dual functions of 2 master stations/secondary stations at the DNP 3.0 level, equipped with 3 fully isolated serial ports (RS-232/422/485), designed for SCADA systems in power, water conservancy, oil and gas, etc., to achieve reliable data interconnection between PLC-5 and DNP 3.0 devices, remote terminals, and SCADA master stations.
I. Model Analysis
MVI71: PLC-5 1771 Platform-specific Series
DNP: DNP 3.0 (Distributed Network Protocol 3.0)
Core Positioning: DNP 3.0 Master Station / Slave Station, Level 2 Compatibility, 3 Independent Fully Isolated Serial Ports, RS-232/422/485, SCADA Communication, Single Slot, Zero PLC Load
II. Core Hardware Specifications
Compatible Platforms
PLC-5: Full series PLC-5/11, /12, /15, /20, /25, /30, /40, /40L, /60, /80, /80E
1771 Backplane, Single-slot Installation
Support for Local / Remote Rack
Backplane Power Consumption: Maximum 800mA @ 5.1VDC ProSoft Technology Inc
Serial Interfaces (3 Ports)
Application Ports (P1, P2, P3): 3 Independent, Jumper selectable RS-232 / RS-422 / RS-485, RJ45 (with DB9 adapter)
RS-232: Point-to-Point Short Distance (15m)
RS-422: Full-Duplex Long Distance (1200m)
RS-485: Half-Duplex Multi-Point (32 Nodes, 1200m)
Electrical Isolation: 500Vrms Optical Isolation (Between Backplane and All Serial Ports) ProSoft Technology Inc
Baud Rate: 110 ~ 115200 bps
Data Format: 8/N/1, 8/E/1, 8/O/1
Protocol Support
DNP 3.0: Master (Master) + Slave (Slave) Dual Mode, Level 2 (Level 2) Compatibility
Function Codes: Support All Standard DNP 3.0 Function Codes
Data Objects: Binary Input, Binary Output, Analog Input, Analog Output, Counter, Floating Point
Data Buffer: 6000 Bytes Bidirectional Shared Database
Master Station Function
Active Polling of 32 DNP Slave Stations
Support for Class 0/1/2/3 Data Polling, Event Triggering, Deadband (Deadband)
Each Port Independent Configuration, Independent Polling List
Slave Station Function
Respond to DNP Master Station Read / Write Requests
Support Event Generation, Active Reporting (Unsolicited Response)
Data Mapping to PLC-5 File Registers
LED Status: OK, BP, P1, P2, P3, ERR Six Sets of Indicators
Operating Environment ProSoft Technology Inc
Temperature: 0°C ~ +60°C
Storage: -40°C ~ +85°C
Humidity: 5% ~ 95% (No Condensation)
Shock Resistance: 30g (Operation), 50g (Non-Operation)
Certification: CE, UL, cURus, RoHS, DNV, GOST-R ProSoft Technology Inc
III. Core Functions and Performance
1. DNP 3.0 Master Station / Slave Station Dual Mode (Core Advantage)
Master Mode (Master)
Active Polling: PLC-5 as the master, periodically / triggeringly reads remote DNP slave station data
32 Slave Stations / Ports: Single Module can connect up to 96 DNP Devices (3 Ports × 32)
Event Driven: Supports Class 1/2/3 Events for Priority Reporting, Improving Real-time Performance Deadband Control: Only upload when the analog quantity exceeds the threshold, reducing network load
Time Synchronization: Supports DNP time synchronization, unified clocks across the entire network
Slave Mode (Slave)
SCADA Access: PLC-5 acts as a slave and connects to the DNP SCADA master system
Unsolicited Reporting: Immediate upload upon event occurrence, no polling required
Data Security: Configurable read/write permissions, address range, password protection
DNP 3.0 Level 2 Compatibility
100% Compatible with IEC 60870-5 Standard
Supports Confirmation/Non-Confirmation Services, Segmented Transmission, Timestamp, Event Classification
Industrial-grade Reliability: Link Confirmation, Automatic Redundancy, Timeout Handling, Error Diagnosis
2. Three Full Isolated Serial Ports (High Flexibility)
Three ports are completely independent
P1/P2/P3 do not interfere with each other, independently configured protocols, parameters, polling lists
Three Links Parallel: Connect multiple DNP devices and SCADA master station simultaneously
RS-232/422/485 Three Modes
Compatible with Point-to-Point, Long Distance, Multi-Point Bus All Topologies
500V Full Isolation: Anti-surge, anti-static, elimination of ground circulating current, protecting PLC and field devices
Multi-point Network
RS-485 Supports 32 Nodes, Saves Wiring, Reduces Cost
3. Deep Integration with PLC-5 System
PLC-5 Memory Mapping
6000-byte Shared Database: Direct mapping of PLC-5 files (N, B, F, T, C files)
BTR/BTW Block Transmission: Efficient data interaction, zero PLC programming
Module Status, Port Status, Slave Status, Event, Error Fully mapped to PLC Tags
Configuration Tool
ProSoft Configuration Builder (PCB): Visual Configuration
DNP Master/Slave Parameters, Polling Lists, Event Classes, Deadband, Mapping Rules Graphical Editing
Online Diagnosis: Real-time Monitoring, Packet Capture, Event Log, Error Tracking, Communication Statistics
4. Industrial-grade Reliability (SCADA Level)
Full Electrical Isolation
500Vrms Triple Isolation: Port - Port, Port - Backplane, Port - Power Full Isolation
Stable Operation in Industrial Field: Strong Interference, Ground Potential Difference, Lightning Strike Environment
Powerful Diagnosis and Fault Tolerance
Link Status, Slave Status, Communication Quality, Error Count Real-time Monitoring
Breakout Automatic Reconnection, Command Retry, Event Buffering, Fault Isolation
Detailed Event Log, Error Code, Diagnostic Information, Quick Troubleshooting
Independent Operation
Zero PLC CPU Load, Does Not Affect Scan Cycle
Module Failure Does Not Affect PLC Host
Four. Core Features and Advantages
1. Professional DNP 3.0 SCADA Communication
Master + Slave Dual Mode: Fully compatible with SCADA networking
DNP 3.0 Level 2: 100% Compatible with Power/Water Standards
3 Independent Isolated Serial Ports: Three times connection capacity, saves slots
Event-driven + Deadband + Active Reporting: Efficient, Real-time, Low Bandwidth Usage
500V Full Isolation: SCADA Level Industrial Protection
2. Optimized for PLC-5
1771 Single Slot: Compatible with all PLC-5, Protects Old System Investment
6000-byte Database: Satisfies Large-scale SCADA Data Volume
BTR/BTW Efficient Transmission: Native Data Interaction of PLC-5
Zero PLC Load: Does Not Affect Control System Performance
3. Flexible, Universal, Easy to Use RS-232/422/485 Three Modes: Fully compatible with all topologies
32 Slave Stations / Ports: Large capacity, high scalability
PCB Visual Configuration: Quick deployment, no underlying programming required
Sample Program + AOI: Out-of-the-box ready, shortens development cycle
Wide temperature range, shock-resistant, no fan: Long-term stability, maintenance-free
4. Industry Standard Certification
Preferred in the power / water conservancy / oil and gas industries
UL/cUL, CE, RoHS, DNV, GOST-R Global Certification by ProSoft Technology Inc
3-year warranty, global technical support
VII. Typical Application Scenarios
PLC-5 Access SCADA: PLC-5 acts as a DNP slave station to access the power / water conservancy SCADA master station
PLC-5 Polling Remote Terminal: PLC-5 acts as a DNP master station to poll RTU, FTU, DTU, and instruments
Multi-system Interconnection: PLC-5 ↔ Third-party DNP PLC, PAC, controller Data exchange
Power Automation: Substation, distribution network, power plant PLC-5 system DNP 3.0 communication
Water Conservancy and Irrigation: Reservoir, water plant, pumping station SCADA system integration
Oil and Gas Pipelines: Long-distance pipeline RTU and PLC-5 interconnection
Renovation of Old Plants: PLC-5 outdated system Upgrade to DNP 3.0 network to protect investment
VIII. Summary
MVI71-DNP is the flagship solution for PLC-5 platform DNP 3.0 SCADA communication. With DNP 3.0 master station / slave station dual mode, level 2 compatibility, 3 independent fully isolated serial ports (RS-232/422/485), 6000-byte large-capacity database, event-driven, dead zone control, active reporting, zero PLC load, industrial-level full isolation, deep integration of PLC-5, and global certification as the core advantages. ProSoft Technology Inc. is designed specifically for SCADA system integration, PLC-5 access to DNP network, remote terminal polling, multi-system interconnection, old plant renovation, and is a high-performance, highly reliable, one-stop SCADA standard module for Rockwell PLC-5 accessing DNP 3.0 industrial network.
Get a Quote