Product Description of ProSoft MVI69-DNPSNET
May 16, 2026

Product Description of ProSoft MVI69-DNPSNET

MVI69-DNPSNET (DNP 3.0 Ethernet Server Network Interface Module) is a DNP 3.0 Ethernet server communication module specially designed by ProSoft for the Rockwell CompactLogix/MicroLogix 1500 platform. Through a single 10/100Mbps Ethernet interface, it supports DNP 3.0 Level 2 and some Level 3 functions. As a slave station (Server), it responds to instructions from the SCADA master station to achieve high-speed integration of CompactLogix with DNP Ethernet networks in the power, water conservancy, and oil/gas industries.

Description

Product Description of ProSoft MVI69-DNPSNET

MVI69-DNPSNET (DNP 3.0 Ethernet Server Network Interface Module) is a DNP 3.0 Ethernet server communication module specially designed by ProSoft for the Rockwell CompactLogix/MicroLogix 1500 platform. Through a single 10/100Mbps Ethernet interface, it supports DNP 3.0 Level 2 and some Level 3 functions. As a slave station (Server), it responds to instructions from the SCADA master station to achieve high-speed integration of CompactLogix with DNP Ethernet networks in the power, water conservancy, and oil/gas industries. 

I. Model Analysis

MVI69: Specialized module for CompactLogix / MicroLogix 1769 platform

DNP: DNP 3.0 (Distributed Network Protocol) - Distributed Network Protocol

S: Server (Slave mode)

NET: Ethernet interface

Core Positioning: Single-port Ethernet, DNP 3.0 slave, TCP/UDP transmission, event active upload, industrial-level isolation, SCADA dedicated

II. Core Hardware Specifications

Compatible Platforms:

CompactLogix: L20, L30, L35, L43, L45 (L43/L45 need to be installed in the first 2 slots of the rack) MicroLogix 1500 LRP

Incompatibility: 1769-L23E-QBFC1B, 1769-L16x, 1769-L18x

Slot occupation: Single slot (standard 1769 size)

Backplane power consumption: 800mA @ 5.1VDC

Ethernet interface (1 port):

Standard: 10/100Base-TX adaptive

Connector: RJ45

Isolation: 1500Vrms electrical isolation

Transmission protocol: TCP/UDP

IP configuration: Static IP/DHCP automatic acquisition

Configuration port (CFG): RS-232 (RJ45→DB9), used for module configuration, firmware upgrade

Internal database: Maximum 4000 word registers (user can customize data mapping)

Slave connection ProSoft Technology Inc: Up to 32 concurrent master station connections (TCP 1, UDP 31)

Event cache:

Digital input (BI): 1000 events

Analog input (AI): 400 events

Floating point input (Float): 200 events

Data point support:

Digital input (BI): 2000 points

Digital output (BO): 500 points

Analog input (AI): 2000 points

Analog output (AO): 500 points

Floating point input (Float): 1000 points

LED status: OK, APP, ERR, LINK, ACT five groups of indicator lights

Operating temperature: 0°C ~ +60°C

Storage temperature: -40°C ~ +85°C

Humidity: 5% ~ 95% (no condensation)

Certification: CE, UL, cURus, RoHS, ATEX Class I Div 2

III. Core Functions and Performance

1. DNP 3.0 Ethernet protocol support (core advantage)

Slave mode (Server):

As a DNP 3.0 slave, respond to SCADA master station (such as dispatch center, RTU) read/write instructions

Support DNP 3.0 Subset Level 2 + Partial Level 3 functions

Dual transmission protocol ProSoft Technology Inc:

TCP: reliable connection, supports active upload (Unsolicited Response) events

UDP: connectionless, high-speed polling, supports concurrent access by multiple master stations

Event-driven communication:

Change report (RBE): automatically report data when out of dead zone

Active upload (Unsolicited): event pushed to the master station (only TCP)

Timestamp: all events with precise time stamp (supports SNTP synchronization)

Data classification: Class 0/1/2/3 data classification, optimizes SCADA polling efficiency

Dead zone control: analog dead zone configurable, reduces invalid communication

Cold / Hot start: supports module cold start, hot start, configuration not lost

2. Ethernet communication characteristics

Electrical isolation: 1500Vrms isolation, anti-interference, surge protection, protects PLC

Multiple master station concurrent ProSoft Technology Inc:

TCP: 1 connection (supports active upload)

UDP: 31 connections (high-speed polling)

Total: 32 master stations accessing simultaneously

Network delay: < 5ms (Ethernet data exchange)

Remote communication: supports cross-subnet, routing, fiber optic, wireless Ethernet DNP communication

3. Backplane high-speed communication (PLC interaction) Asynchronous exchange: The data interaction between the module and the PLC is independent of the DNP network and does not occupy the PLC scanning time.

Data mapping: A 4000-word database directly maps the PLC controller labels.

Interaction mode:

Periodic I/O data mirroring

Ladder diagram AOI, MSG instructions control

Real-time reporting of status, error codes, and events

Transmission delay: < 1ms (backplane high-speed bus)

4. Configuration and diagnosis

Configuration software: ProSoft Configuration Builder (PCB)

Visual configuration of IP, slave station parameters, data points, dead zones, events

Configuration file download, backup, batch copying

Online diagnosis:

Ethernet connection status, traffic monitoring, error count

Master station access records, command responses, event logs

Module operation status, fault codes, health monitoring

Four. Core features and advantages

1. Seamless integration of AB system

Native compatibility: Specifically designed for CompactLogix/MicroLogix, single slot, backplane power supply

Plug-and-play: The PLC automatically recognizes as an I/O module, no additional programming required

Label mapping: DNP data directly converted to PLC labels, simplifying program development

Program support: Provide Studio 5000 AOI, ladder diagram routines, configuration examples

2. Professional-level DNP 3.0 Ethernet functions

High-speed Ethernet: 10/100Mbps bandwidth, 100 times faster than serial ports

Multi-master station concurrent ProSoft Technology Inc: 32 master stations can access simultaneously, meeting the requirements of large-scale SCADA

Event-driven: RBE + active upload, significantly reducing network load

Hierarchical data: Class 0/1/2/3 optimized polling, improving system response

Mass data points: 2000 AI/2000 BI/500 AO/500 BO, meeting the requirements of large projects

Time synchronization: Support SNTP network time synchronization, events can be precisely traced

3. Industrial-grade reliability

Electrical isolation: 1500Vrms isolation surge, interference, ground potential difference

Independent operation: Module failure does not affect the PLC host

Power loss protection: Built-in battery, configuration, events, timestamps will not be lost for 10 years

Wide temperature design: 0~60℃, suitable for harsh environments in power, water conservancy, oil and gas

Dual protocol redundancy ProSoft Technology Inc: TCP/UDP dual protocols, automatic switching when the master station fails

5. Efficient development and easy maintenance

Visual configuration: Drag-and-drop configuration in PCB software, rapid deployment

Online debugging: Real-time monitoring of events, communication status, quick fault location

Batch application: One-click copy of configuration files, rapid production at multiple sites

Remote diagnosis: Support remote configuration, firmware upgrade, event viewing

Six. Typical application scenarios

Power SCADA system: Substations, distribution networks, power plants CompactLogix connected to DNP Ethernet SCADA

Water conservancy monitoring: Reservoirs, gates, pumping stations, water quality monitoring DNP Ethernet integration

Oil and gas long-distance transmission: Pipeline pressure, flow, valve control DNP remote monitoring

Municipal public utilities: City water supply, gas, sewage SCADA system

Industrial energy management: Factory power monitoring, intelligent instruments, power quality analysis

Smart grid: Distributed energy, micro-grid, energy storage system DNP Ethernet access

Upgrade of outdated systems: DNP devices without Ethernet connected to modern SCADA network

Summary MVI69-DNPSNET is an industrial standard solution for DNP 3.0 Ethernet communication on the CompactLogix platform. With single-channel isolated Ethernet, DNP 3.0 slave station mode, dual protocols of TCP/UDP, 32 concurrent master stations, active event upload, 4000-byte large data buffer, seamless compatibility with all AB series, industrial-grade reliability, and visual configuration as its core advantages, it is specifically designed for SCADA system integration, remote monitoring, and upgrading of old equipment in industries such as power, water conservancy, oil and gas, and municipal public utilities. It is the preferred communication module for achieving high-speed interconnection and communication between Rockwell PLC and DNP 3.0 Ethernet networks.