GE 710-1144 Totalizer & Frequency Output Option PCB
July 23, 2026

GE 710-1144 Totalizer & Frequency Output Option PCB

GE 710-1144 is the assembly drawing number matching the 703-1144 series circuit board, an optional plug-in board exclusively for GE DigitalFlow 868/GS868 ultrasonic flow transmitters. It provides pulse frequency output and flow totalizer signal expansion functions for flow accumulation and peripheral counter connection

Description

710 serial numbers represent GE Panametrics official assembly drawing identifiers, while 703-1144 is the actual circuit board hardware part number; 710-1144 corresponds to the overall assembly specification of the totalizer/frequency output board, applicable to the full 868 platform including XMT868, AT868, GC868, GF868 and GS868 ultrasonic flow hostsManualsLib. This board adopts an internal card slot plug-in design, which can be installed in the reserved expansion slot of the flowmeter mainframe to expand the signal output capability on the basis of the original analog and communication interfaces.
The core function of the board is to convert real-time flow data into standard frequency pulse signals and cumulative total pulse signals. The frequency output is linearly proportional to the instantaneous flow rate, which can be directly connected to secondary instruments, PLC pulse counting modules and data acquisition modules; the built-in hardware totalizer independently accumulates positive flow volume, realizing local flow total recording without relying on upper computer system calculation, which improves the reliability of metering statistics for energy settlement and material balance occasions.
The PCB surface is coated with three-proof conformal coating to resist moisture, dust and slight corrosive gas interference in industrial instrument cabinets, and can operate stably in the ambient temperature range of -20℃ ~ +60℃. The onboard signal isolation circuit effectively isolates the flowmeter internal circuit from external field equipment to prevent backflow current and electromagnetic interference from damaging the main control motherboard. The board size, pin definition and card slot buckle structure are fully matched with the original 868 series chassis, supporting hot plug-free offline installation and commissioning without modifying the main machine wiring.
The output pulse amplitude, pulse weight and totalizer reset mode can be configured through the flowmeter local panel menu. It is widely matched with batching control systems, flow total display instruments and factory energy management systems. Each 710-1144 assembly undergoes pulse output accuracy testing and long-term power aging verification before delivery to ensure the consistency of cumulative metering accuracy. There are no mechanical wearable components on the circuit board itself, with extremely low failure rate during long-term operation.
Daily maintenance only requires regular inspection of the terminal wiring fastening state and surface dust cleaning. When the flowmeter cannot output pulse signals or the totalizer value is abnormal, replacing this optional board can quickly eliminate faults, avoiding the overall replacement of expensive flow transmitter equipment and reducing maintenance costs and system downtime losses. It is a common extended spare part for industrial ultrasonic flow measurement systems that need flow pulse output and independent totalizing functions.