MDX60A0110-5A3-4-0
May 28, 2026

MDX60A0110-5A3-4-0

Model Code Definition MDX60A: MOVIDRIVE MDX60A series AC drive 0110: Rated output power 11 kW 5: 3-phase AC input, voltage range 380 V ~ 500 V A3: Standard version with built-in EMC/RFI filter 4: Integrated brake chopper, supporting 4-quadrant operation 0: Standard hardware configuration

Description

1. Model Code Definition

  • MDX60A: MOVIDRIVE MDX60A series AC drive

  • 0110: Rated output power 11 kW

  • 5: 3-phase AC input, voltage range 380 V ~ 500 V

  • A3: Standard version with built-in EMC/RFI filter

  • 4: Integrated brake chopper, supporting 4-quadrant operation

  • 0: Standard hardware configuration

2. Electrical Parameters

Mains Input

  • Rated voltage: 3×380 V (-10%) to 3×500 V (+10%)

  • Input frequency: 50/60 Hz ±5%

  • Rated input current: 21.6 A

Motor Output

  • Rated output power: 11 kW

  • Apparent power: 16.8 kVA

  • Rated output current: 24 A (4 kHz PWM)

  • Output voltage: 0 to full input voltage

  • Output frequency: 0–180 Hz (VFC mode); 0–500 Hz (vector mode)

  • Overload capability: 125% rated load for 60 seconds, 150% rated load for 3 seconds

  • Adjustable PWM frequency: 4 kHz, 8 kHz, 16 kHz

  • Brake chopper: Integrated for regenerative load applications

3. Control & Main Functions

  • Control modes: VFC sensorless voltage/frequency control, CFC encoder-based vector control

  • Speed range: -6000 rpm to +6000 rpm, speed resolution: 0.2 rpm

  • Automatic motor parameter identification

  • Flying restart function for running motors

  • Energy saving mode for light load operation

  • Stable speed regulation and fast dynamic response

4. I/O and Communication

  • Analog input: 0–10 V / -10 V ~ +10 V for speed setpoint

  • Multiple programmable 24 V DC digital inputs and relay outputs

  • Dedicated port for motor thermistor thermal protection

  • Built-in SBus system bus; optional expansion for Profibus DP, CANopen and Modbus RTU

5. Mechanical and Environmental Data

  • Protection class: IP20 (indoor cabinet installation)

  • Cooling type: Forced air cooling with temperature-controlled fan

  • Operating ambient temperature: 0 °C ~ +40 °C. Power derating 2% per °C above 40 °C

  • Storage temperature: -25 °C ~ +70 °C

6. Protection Functions

Comprehensive protection including overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short circuit and motor overheat. The drive will trigger alarm and perform safe stop when faults occur.

7. Typical Applications

Conveyor systems, hoisting equipment, packaging machines, pumps, fans and other industrial automation equipment with frequent deceleration and regenerative loads.

8. Compliance & Certifications

Comply with CE, UL 508C, CSA and RoHS requirements. Conform to standards EN 61800-3 and EN 60204-1.


Get a Quote