MDV60A0750-503-4-49 (SEW MOVIDRIVE MDV60A Inverter)
Description
Technical Specifications
Input: 3-phase AC 380–500 V, 50/60 Hz, 117 A
Output: 75.0 kW, 130 A, 91 kVA, frequency range: 0–400 Hz
Control modes: VFC (open-loop vector control), CFC (closed-loop vector control with encoder)
Overload capability: 150% rated load for 60 seconds; 200% rated load for 3 seconds
Protection class: IP00 (IP10 with protective cover)
Ambient temperature: 0 °C to +40 °C for full load operation
Dimensions (Width × Height × Depth): 320 × 610 × 350 mm
Weight: 35.0 kg
Key Features
No integrated RFI filter, suitable for systems equipped with external EMC filters
4-quadrant design enables fast braking and energy recovery
Special firmware pre-configured with functions and parameters for customized industrial applications
Built-in IPOSplus® positioning function as standard
Compatible with PROFIBUS, CANopen, Modbus and SBus communication protocols
Comprehensive protection against overvoltage, overcurrent, overtemperature, stall and earth fault
Typical Applications
Heavy-duty conveyors and bulk material handling equipment
Industrial fans, pumps and heavy processing machinery
Systems requiring customized motion control and dedicated function settings
Speed and torque control for 75 kW asynchronous motors with external EMC solutions
Related Model Variants
MDV60A0750-503-4-00: 75.0 kW, no RFI filter, standard firmware
MDV60A0750-5A3-4-00: 75.0 kW, with integrated RFI filter, standard firmware
MDV60A0550-503-4-49: 55.0 kW, no RFI filter, custom 49 firmware
Get a Quote