Model Decoding MDV stands for vector control inverter for asynchronous motors. 60A refers to MOVIDRIVE 60A series. 0055 indicates the rated power of 5.5 kW. 5A3 means 3-phase 380–500 V AC power supply with integrated RFI filter. 4 represents 4-quadrant operation equipped with built-in brake chopper. 0T means the unit is installed with preloaded dedicated application firmware.

Description

Technical Specifications

  • Input: 3-phase AC 380–500 V, 50/60 Hz, 11.5 A

  • Output: 5.5 kW, 12.5 A, 8.8 kVA, frequency range: 0–180 Hz

  • Control modes: VFC (open-loop vector control), CFC (closed-loop vector control with encoder)

  • Overload capability: 150% rated load for 60 s; 200% rated load for 3 s

  • Protection class: IP20

  • Ambient temperature: 0 °C ~ +40 °C (full load operation)

  • Dimensions (W × H × D): 105 × 273 × 315 mm

  • Weight: 3.5 kg

Key Features

  • Integrated RFI filter complies with EN 55011 Class B for EMC compliance

  • 4-quadrant design enables fast braking and energy recovery

  • Factory preloaded application firmware for quick commissioning and dedicated process functions

  • Supports both open-loop and closed-loop vector control

  • Compatible with PROFIBUS, CANopen, Modbus and SBus communication protocols

  • Comprehensive protection against overvoltage, overcurrent, overtemperature, stall and earth fault

Typical Applications

  • Conveyors and material handling equipment

  • Fans, pumps and medium-duty processing machinery

  • Packaging and textile machinery requiring preset motion functions

  • Industrial automation systems driven by asynchronous motors

Related Model Variants

  • MDV60A0055-5A3-4-00: 5.5 kW, with RFI filter and standard firmware

  • MDV60A0055-503-4-0T: 5.5 kW, without RFI filter and with application firmware

  • MDV60A0055-5A3-4-04: 5.5 kW, with RFI filter and conformal coated PCB for harsh environments