PXI-6514
May 27, 2026

PXI-6514

I. Product Introduction The PXI-6514 is an industrial-grade 64-channel isolated digital input/output module from NI (Emerson). It is a 3U single-slot PXI, featuring 32 bidirectional inputs + 32 source outputs, ±30 V wide voltage, 350 mA/channel, 8 groups of 250 Vrms isolation, with a watchdog, programmable power-on, input filtering. It is the main product for high-reliability industrial monitoring and source output control. It is currently in production.

Description

II. Model Interpretation

PXI: 3U single slot, standard PXI bus (compatible with PXIe mixed slots)

6514: 651x industrial isolated DIO series, **32 DI (bidirectional) + 32 DO (source output)** isolated type

Architecture: 8 groups (Bank 0–7) × 8 channels, 250 Vrms isolation between groups

Part Number: 778965-01

Location: Complementary to **PXI-6513 (sink output) / 6515 (high flow)**, source output preferred

III. Technical Parameters (25℃)

1. Digital Input (DI)

Channels: 32 bidirectional (Sink/Source compatible)

Voltage range: -30 VDC to +30 VDC

Logic threshold: High ≥ +11 V, Low ≤ +4 V (24 V industrial standard)

Input filtering: Software programmable 1 μs to 1 ms (debouncing / de-sagging) NI

Response delay: Typical 75 μs

2. Digital Output (DO)

Channels: 32 source outputs (Source)

Voltage range: 0 to 30 VDC

Drive capability: 350 mA/channel continuously (PNP type load) NI

Isolation: 250 Vrms between groups (1 minute), common ground between channels NI

Power-on status: Programmable (all off / all on / hold) NI

Watchdog: Software failure automatic safe state (settable) NI

3. Physical and Environmental

Size: 3U single slot (22×124×126 mm)

Operating temperature: 0 to 55℃ (Industrial extended -20 to 70℃ selectable)

Power consumption: Approximately 2.4 W (300 mA@+3.3 V, 250 mA@+5 V)

Calibration: No regular calibration required

IV. Interface and Communication Configuration

Front panel interface: 100-pin anti-idle SCSI female connector

Adapter cable: SH100-100, R1005050 (100-pin to 2×50-pin)

Terminal box: CB-100, SCB-100A (with isolation terminals)

Bus: PXI (PCI, trigger, 10 MHz reference clock)

Driver: NI-DAQmx 9.0+, supports LabVIEW, Python, C#, TestStand

Synchronization: PXI trigger bus, multi-module synchronous acquisition and control

V. Core Functions

32DI+32DO isolation + 350 mA source output: Single card monitoring 32 sensors + driving 32 PNP relays / SSR, no external driver required, group-to-group isolation to resist ground current and high voltage interference.

Industrial-grade safety mechanism: Watchdog + programmable power-on + input filtering + change detection, software crash automatic protection, default safe state upon power-on, contact debouncing to prevent false triggering NI.

±30 V wide voltage bidirectional input: Compatible with NPN/PNP sensors, compatible with global 24 V industrial standard.

High-density single slot: 64 channels 3U single slot, saves chassis slots, suitable for large-scale I/O mixed systems.

Strong anti-interference isolation: 250 Vrms group-to-group isolation to prevent high voltage from entering the PXI system, protecting equipment and personnel safety.

VI. Application Scenarios

Industrial automation "monitoring + source output control": PLC expansion DIO, 24 V sensor acquisition + PNP relays / valve control, production line status feedback + actuator drive. Power and Energy System: Switch cabinet status monitoring + Open-close control, circuit breaker position feedback + Drive, relay protection contact collection + Execution circuit.

Automotive Electronic Testing: BCM analog quantity collection + Load driving, vehicle lights / wipers / door lock status monitoring + Control.

ATE and Test System: Relay matrix monitoring + Control, test fixture status collection + Drive, safety interlock signal closed loop.

Railway / Ship Control: On-board / shipboard analog quantity monitoring + Actuator control, door control / lighting / alarm signal closed loop, integrated in strong interference environment.

VII. Installation and Maintenance Instructions

Installation and Power On

Disconnect the power supply card, ensure the chassis is reliably grounded; after powering on, NI-DAQmx self-checks, no preheating required.

Operating Temperature: 0–55℃, keep the air duct unobstructed, avoid overloading due to high temperature.

Wiring and Operation

Avoid frequent plugging and unplugging of 100-pin interface, recommended to use CB-100 isolation wiring box for intermediate transfer.

Input Voltage: **≤±30 V**, Output current per channel **≤350 mA**,Strictly prohibitedshort circuit; Use shielded twisted pair for long-distance, keep away from strong electricity / motors.

Filtering Time: Set according to contact characteristics (10–50 ms), Watchdog timeout time set according to safety requirements (100–500 ms).

Daily Maintenance

Keep interfaces clean, prevent dust accumulation in long-term idle state; No calibration required, regularly check the tightness of wiring terminals.

Isolation Layer: Regular insulation test (250 Vrms/1 minute) to ensure isolation performance.