PXI: 3U single slot, standard PXI bus (compatible with PXIe mixed slots)
6514: 651x industrial isolated DIO series, **32 DI (bidirectional) + 32 DO (source output)** isolated type
Architecture: 8 groups (Bank 0–7) × 8 channels, 250 Vrms isolation between groups
Part Number: 778965-01
Location: Complementary to **PXI-6513 (sink output) / 6515 (high flow)**, source output preferred
III. Technical Parameters (25℃)
1. Digital Input (DI)
Channels: 32 bidirectional (Sink/Source compatible)
Voltage range: -30 VDC to +30 VDC
Logic threshold: High ≥ +11 V, Low ≤ +4 V (24 V industrial standard)
Input filtering: Software programmable 1 μs to 1 ms (debouncing / de-sagging) NI
Response delay: Typical 75 μs
2. Digital Output (DO)
Channels: 32 source outputs (Source)
Voltage range: 0 to 30 VDC
Drive capability: 350 mA/channel continuously (PNP type load) NI
Isolation: 250 Vrms between groups (1 minute), common ground between channels NI
Power-on status: Programmable (all off / all on / hold) NI
Watchdog: Software failure automatic safe state (settable) NI
3. Physical and Environmental
Size: 3U single slot (22×124×126 mm)
Operating temperature: 0 to 55℃ (Industrial extended -20 to 70℃ selectable)
Power consumption: Approximately 2.4 W (300 mA@+3.3 V, 250 mA@+5 V)
Calibration: No regular calibration required
IV. Interface and Communication Configuration
Front panel interface: 100-pin anti-idle SCSI female connector
Adapter cable: SH100-100, R1005050 (100-pin to 2×50-pin)
Terminal box: CB-100, SCB-100A (with isolation terminals)
Bus: PXI (PCI, trigger, 10 MHz reference clock)
Driver: NI-DAQmx 9.0+, supports LabVIEW, Python, C#, TestStand
Synchronization: PXI trigger bus, multi-module synchronous acquisition and control
V. Core Functions
32DI+32DO isolation + 350 mA source output: Single card monitoring 32 sensors + driving 32 PNP relays / SSR, no external driver required, group-to-group isolation to resist ground current and high voltage interference.
Industrial-grade safety mechanism: Watchdog + programmable power-on + input filtering + change detection, software crash automatic protection, default safe state upon power-on, contact debouncing to prevent false triggering NI.
±30 V wide voltage bidirectional input: Compatible with NPN/PNP sensors, compatible with global 24 V industrial standard.
High-density single slot: 64 channels 3U single slot, saves chassis slots, suitable for large-scale I/O mixed systems.
Strong anti-interference isolation: 250 Vrms group-to-group isolation to prevent high voltage from entering the PXI system, protecting equipment and personnel safety.
VI. Application Scenarios
Industrial automation "monitoring + source output control": PLC expansion DIO, 24 V sensor acquisition + PNP relays / valve control, production line status feedback + actuator drive. Power and Energy System: Switch cabinet status monitoring + Open-close control, circuit breaker position feedback + Drive, relay protection contact collection + Execution circuit.
Automotive Electronic Testing: BCM analog quantity collection + Load driving, vehicle lights / wipers / door lock status monitoring + Control.
ATE and Test System: Relay matrix monitoring + Control, test fixture status collection + Drive, safety interlock signal closed loop.
Railway / Ship Control: On-board / shipboard analog quantity monitoring + Actuator control, door control / lighting / alarm signal closed loop, integrated in strong interference environment.
VII. Installation and Maintenance Instructions
Installation and Power On
Disconnect the power supply card, ensure the chassis is reliably grounded; after powering on, NI-DAQmx self-checks, no preheating required.
Operating Temperature: 0–55℃, keep the air duct unobstructed, avoid overloading due to high temperature.
Wiring and Operation
Avoid frequent plugging and unplugging of 100-pin interface, recommended to use CB-100 isolation wiring box for intermediate transfer.
Input Voltage: **≤±30 V**, Output current per channel **≤350 mA**,Strictly prohibitedshort circuit; Use shielded twisted pair for long-distance, keep away from strong electricity / motors.
Filtering Time: Set according to contact characteristics (10–50 ms), Watchdog timeout time set according to safety requirements (100–500 ms).
Daily Maintenance
Keep interfaces clean, prevent dust accumulation in long-term idle state; No calibration required, regularly check the tightness of wiring terminals.
Isolation Layer: Regular insulation test (250 Vrms/1 minute) to ensure isolation performance.