PXI-6071E
Description
II. Model Interpretation
PXI: 3U single slot, PXI bus, compatible with PXI/PXIe chassis.
6071E: E-series high-density high-speed model, 12-bit, 1.25 MS/s, 64-channel AI multi-functional I/O.
Part number: 777676-01 (standard).
III. Technical Parameters (25℃)
1. Analog Input (AI)
Channels: 64 single-ended / 32 differential (software selectable)
Resolution: 12 bits
Total sampling rate: 1.25 MS/s
Range: ±0.05 V to ±10 V (14 programmable levels)
Input impedance: 1 MΩ || 20 pF
Coupling: DC coupling; overvoltage protection (on power-up ±25 V, off power-down ±15 V)
FIFO: 512 samples, supports DMA high-speed continuous acquisition
2. Analog Output (AO)
Channels: 2
Resolution: 12 bits
Range: ±10 V
Refresh rate: 1 MS/s (per channel)
Drive: ±5 mA; output impedance ≤ 0.1 Ω
3. Digital I/O (DIO)
Channels: 8 bidirectional TTL
Level: TTL (high ≥ 2.4 V, low ≤ 0.4 V)
Rate: Maximum 1 MHz
4. Counter / Timer
Quantity: 2 24-bit
Function: event counting, frequency / period measurement, pulse generation
Time base: 20 MHz internal clock
5. Physical and Environmental
Size: 3U single slot (approximately 22×124×126 mm)
Operating temperature: 0 to 55℃
Power consumption: approximately 7 W (PXI backplane power supply)
IV. Interface and Communication Configuration
Front panel interface: 68-pin SCSI type (with SH68-68-EP cable, CB-68LP wiring box)
Bus: standard PXI (PCI, trigger, 10 MHz reference clock)
Driver: NI-DAQmx, supports LabVIEW, TestStand, Python, C#
Synchronization: PXI trigger bus / RTSI, multi-module clock and trigger synchronization
PFI lines: 8 programmable function inputs for board-to-board / board-to-board digital and timing signal routing
V. Core Functions
64-channel high-density acquisition: 64 single-ended / 32 differential, channel count is 4 times that of 6070E, suitable for large-scale measurement points.
1.25 MS/s high-speed sampling: 12-bit accuracy, suitable for medium-high-speed scenarios such as vibration, shock, and transient signals.
Multifunctional integration: AI + AO + DIO + counter, one module completes measurement, control, and timing.
Wide range and signal conditioning: 14 levels of range; compatible with SCXI/SCC conditioning, suitable for thermocouples, RTD, and high-voltage signals.
High-speed streaming disk capability: 512 samples FIFO + DMA, supports 1.25 MS/s continuous data storage.
VI. Application Scenarios
Multi-channel vibration / modal testing: large-scale structures, wind turbine blades, automotive整车 multi-measurement point synchronous acquisition.
Industrial process large-scale monitoring: multiple nodes of pressure, temperature, flow fast-changing signals synchronous acquisition.
Semiconductor / electronic ATE testing: multi-pin devices, PCB functional high-speed parallel testing.
Research and laboratory automation: multi-sensor array, biological signals (EEG/ECG) synchronous recording.
High-density low-cost measurement and control system: 64 channels + 1.25 MS/s, balancing channel count, speed, and cost.
VII. Installation and Maintenance Instructions
Installation and Power On
Insert the single slot when power is off, chassis reliably grounded; After powering on, NI-DAQmx performs self-check and preheats for 15 minutes.
Operating temperature: 0 - 55℃. Keep the air duct unobstructed and avoid blocking the fan.
Connections and operations
Use shielded twisted-pair cables for analog inputs; differential connections are preferred in strong interference scenarios.
Input voltage should not exceed ±10 V; avoid frequent plugging and unplugging of the 68-pin interface; it is recommended to be connected to a wiring box.
When synchronizing multiple modules, share the PXI 10 MHz reference and trigger bus.
Daily maintenance and calibration
It is recommended to conduct a traceable calibration once a year; built-in self-calibration compensates for temperature drift.
Keep the interface clean, prevent dust accumulation during long-term inactivity; keep away from strong vibrations and condensation.
Get a Quote