PXI-6030E
Description
II. Model Interpretation
PXI: Compliant with the PXI bus, 3U single slot, compatible with PXI/PXIe chassis.
6030E: A high-precision model of the NI E series, representing 16-bit, 100 kS/s, 16-channel multi-functional I/O.
Part Number: 777555-01 (standard).
III. Technical Specifications (25℃)
1. Analog Input (AI)
Channels: 16 single-ended / 8 differential (software selectable)
Resolution: 16 bits (4 bits higher than 6025E)
Sampling Rate: 100 kS/s (total sampling), multiplexed across multiple channels
Range: ±0.1 V to ±10 V (software programmable)
Input Impedance: 1 MΩ
Coupling: DC coupling, overvoltage protection (on power-on ±25 V, off power-on ±15 V)
Accuracy: ±0.5 LSB relative accuracy, ±1 LSB maximum DNL, 16-bit ensures monotonicity
2. Analog Output (AO)
Channels: 2 channels
Resolution: 16 bits
Range: ±10 V
Drive: ±5 mA, output impedance ≤ 0.1 Ω
Refresh Rate: 100 kS/s (per channel)
3. Digital I/O (DIO)
Channels: 8 bidirectional TTL
Level: TTL (high ≥ 2.4 V, low ≤ 0.4 V)
Rate: Maximum 1 MHz
4. Counter / Timer
Quantity: 2 24-bit channels
Function: event counting, pulse generation, frequency / period measurement
Timebase: 100 MHz internal clock
5. Physical and Environmental
Size: 3U single slot (approximately 22 mm × 124 mm × 126 mm)
Operating Temperature: 0 to 55℃
Power Consumption: Approximately 5 W (PXI backplane power supply)
IV. Interface and Communication Configuration
Front Panel / Connectors
68-pin SCSI type I/O interface (with SH68-68-EP cable and CB-68LP wiring box)
No front panel indicator lights, status read by software
Bus and Software
Backplane: PXI bus (PCI, trigger, 10 MHz reference)
Driver: NI-DAQmx, supports LabVIEW, TestStand, Python, C#
Synchronization: Supports PXI trigger bus and RTSI bus multi-module synchronization
V. Core Functions
16-bit High-Precision Acquisition: Resolution is 4 times higher than 6025E, suitable for weak signals and precise sensor measurements.
Flexible Multi-Channel Configuration: 16 single-ended / 8 differential selectable, differential mode suppresses common-mode interference, suitable for industrial sites.
Multifunctional Integration: AI + AO + DIO + Counter, balances measurement, control, and timing, simplifies system architecture.
Industrial-grade Stability: Wide temperature operation, overvoltage protection, high common-mode rejection ratio, suitable for harsh environments.
Rich Signal Conditioning: Supports 70 + SCXI/SCC conditioning modules, compatible with thermocouples, RTD, high voltage, etc.
VI. Application Scenarios
Precise Sensor Measurement: Strain bridge, thermocouple, RTD, photodiode, etc. low-level signal acquisition.
Industrial Process Monitoring: Temperature, pressure, level, flow, etc. high-precision monitoring and closed-loop control.
Laboratory and Research: Physical chemistry experiments, biological signals (EEG/ECG), vibration mode analysis.
Electronic Testing and Verification: PCB function testing, component parameter measurement, low-speed signal calibration.
Small-scale Automation Systems: Balances cost and accuracy, suitable for multi-channel, medium-low speed measurement and control scenarios.
VII. Installation and Maintenance Instructions
Installation and Power On Disconnect the power supply and insert the PXI single slot, with the chassis grounded; after powering on, perform self-checks by NI-DAQmx. It is recommended to preheat for 10 minutes.
Operating temperature: 0 - 55℃. Ensure the air duct is unobstructed and avoid blocking the fan.
Connections and Operations
Use shielded twisted-pair cables for analog input, with differential connection to suppress interference; the input voltage should not exceed ±10 V.
Avoid frequent plugging and unplugging of the 68-pin interface; it is recommended to use a wiring box for transition; perform anti-static operations.
When synchronizing multiple modules, share the PXI 10 MHz reference clock and trigger bus.
Daily Maintenance and Calibration
It is recommended to conduct a traceable calibration once a year to compensate for gain/offset drift; built-in self-calibration corrects temperature drift.
Keep the interface clean and cover it with a dust cover when not in use for a long time; avoid strong vibrations and humid environments.
Get a Quote