PXI4462
Description
Model Explanation PXI-4462
PXI: 3U PXI bus specification
4462: DSA series, 4-channel high-resolution analog input
Full name: PXI Sound and Vibration Module
Compatibility: PXI chassis (3U), used in conjunction with LabVIEW / DAQmx.
Technical parameters
Manufacturer: National Instruments (NI, now part of Emerson)
Channels: 4 synchronous sampling analog inputs (differential / pseudo-differential)
Resolution: 24-bit Δ-Σ ADC
Sampling rate: Up to 204.8 kS/s/channel
Input range (software selectable): ±0.316 V, ±1 V, ±3.16 V, ±10 V, ±31.6 V, ±42.4 V
Coupling: AC/DC per channel independently configurable
Impedance: 1 MΩ (differential)
Dynamic range: Typical 120 dB
THD: Typical -100 dB
Crosstalk: Typical -100 dB
IEPE excitation: 0 mA / 4 mA / 10 mA (software selectable)
Bandwidth: DC–92 kHz (anti-aliasing filter)
Connectors: Front panel 4×BNC
Operating temperature: 0°C ~ +55°C
Size: 3U PXI standard size
Interfaces and communications
Bus: PXI backplane (clock, trigger, data)
Front end: 4×BNC analog input
Trigger: Supports analog/digital trigger, multi-module synchronization
Software: NI-DAQmx, LabVIEW, Sound and Vibration Toolkit
Core functions
High-precision dynamic signal acquisition: 24-bit + 120dB dynamic range, suitable for weak vibration/acoustic signals.
IEPE sensors direct compatibility: Built-in constant current source, directly drives accelerometers, microphones.
Flexible range and coupling: 6 voltage ranges, AC/DC switch, suitable for voltage/charge type sensors.
Synchronization and trigger: Multi-card synchronization, external trigger, supports multi-channel parallel testing.
Anti-aliasing filter: Hardware low-pass, ensures frequency domain measurement accuracy. Application scenario
Automotive: NVH (noise, vibration and acoustic roughness) testing, engine / chassis vibration analysis.
Aerospace: Structural vibration, modal analysis, sensor calibration.
Audio: Speaker/microphone frequency response, distortion, noise testing.
Industrial: Equipment condition monitoring, bearing fault diagnosis, strain / pressure dynamic measurement.
Installation and maintenance Installation
Insert the PXI 3U slot and fix the panel; use BNC connectors for sensors / signal sources.
Install the NI-DAQmx driver, and LabVIEW will automatically recognize and configure it. Maintenance
Regular maintenance: Inspect BNC connectors, shield grounding, and chassis fan cooling.
Calibration: The original factory no longer offers calibration services. Calibration is based on historical records of used parts. Fault diagnosis
No signal: Check IEPE current settings, BNC connection, and sensor power supply.
High noise: Confirm shielding grounding, keep away from strong electricity, and remove AC coupling to filter out DC.
Asynchronous: Check the connection of PXI clock/trigger lines.