PXI-2564
Description
Model Explanation
PXI: Compliant with the PXI bus standard (PCI eXtensions for Instrumentation)
2564: The model number of the NI switch module, defined as 16-channel SPST, 150 V, 5 A, non-latching electromechanical relay
Full Name: PXI-2564 / 778572-64 → 16-Channel, 5 A, SPST PXI Relay Module
Topology Alias: NISWITCH_TOPOLOGY_2564_16_SPST (default 16×SPST) NI Technical Specifications
Switch and Electrical Characteristics
Topology: 16 independent SPST (normally open, Form A); configurable as 8 DPSTNI
Relay Type: Electromechanical, non-latching, gold-plated contacts NI
Maximum Switching Voltage: 150 VDC / 125 VAC (peak) NI
Maximum Switching / Load Current: 5 A (per channel) NI
Maximum Switching Power: 750 VA
On-Resistance (typical): <50 mΩ
Thermal Offset (typical): <1 µV
Bandwidth: DC~10 MHz NI
Action Time (maximum): 10.4 ms
Relay Lifespan:
Mechanical Life: 2×10⁷ times
Full-load Electrical Life: 1×10⁵ times NI
Trigger and Control
Trigger Line: Supports PXI Trigger 0~7
Minimum Trigger Pulse Width: 150 ns
Output Trigger Pulse Width: 1~62 µs programmable (default 2 µs) NI
Physical and Environmental
Form: Standard PXI 3U single slot
Connector: Front panel 37-pin D-SUB (male)
Size (Length × Width × Height): Approximately 216×20×130 mm
Weight: Approximately 0.27 kg
Operating Temperature: 0~55°C
Storage Temperature: -20~70°C
Power Consumption (5 V): Approximately 5 W
Front Panel I/O
37-pin D-SUB (male):
16×SPST mode: 1 COM and 1 NO per channel; 16 independent channels
8×DPST mode: 1 COM and 2 NO per channel; 8 dual-channel switches
Backplane and Driver
Bus Interface: PXI mixed slot (compatible with PXI-1/PXIe)
Power Supply: PXI backplane 5 V power supply
Driver Software: NI-SWITCH, supports LabVIEW, TestStand, CVI, Python, etc.
Software Functions: MAX identification, topology configuration, relay counting, trigger management NI
Core Functions
16 SPST / 8 DPST reconfigurable: Software switch topology, balancing channel density and dual-channel synchronous control NI
High Current / High Voltage Switching Capability: 150 V, 5 A, meeting the switching requirements of most power devices and power paths NI
Low On-Resistance + Low Thermal Offset: suitable for precise current/voltage measurement circuits NI
Hardware Trigger Synchronization: PXI backplane trigger, precise timing accuracy (<1 µs) when multiple modules are synchronized NI
Relay Health Monitoring: On-board closing count, supporting predictive maintenance NI
Field Replaceable Relays: No need for factory return, reducing maintenance costs NI Applicable scenarios
Automotive electronic testing: ECU power circuit, load box, relay/fuse simulation
Military / Aviation: Power distribution, high-power signal routing, electromagnetic coil control
Industrial ATE: Power / load switching in mass production testing, relay module aging test
Energy and power: Battery testing, photovoltaic module testing, high-voltage circuit control
General high-power switches: Replace mechanical switches to achieve automated program-controlled switching
User and maintenance instructions
Installation and configuration
Insert the PXI 3U single slot and fix it.
Install the NI-SWITCH driver, identify the module in MAX and select the topology (16×SPST or 8×DPST).
Connect the 37-pin D-SUB cable, avoid strong pulling and dragging; for high-power circuits, it is recommended to use shielded cables and reliable grounding.
Key operation points
Power limit: Strictly follow the 150 V / 5 A limit; inductive loads (motors, coils) need to be equipped with current-limiting protection to avoid overvoltage breakdown of contacts NI.
Trigger selection:
Low-speed debugging: Software immediate trigger;
High-speed synchronization: PXI hardware trigger (0-7 lines).
Channel independent control: 16 channels can be independently turned on and off, without interference.
Maintenance and calibration
Life monitoring: Read the number of closures through NI-SWITCH, warning for replacement when approaching 1×10⁵ times (full load); NI.
Regular inspection: Check the D-SUB connector for looseness and oxidation every quarter; clean the contacts.
Environmental requirements: Working temperature 0-55°C, humidity 10%-90% (no condensation).
Relay replacement: Replace on-site according to NI manual steps, no professional tools required NI
Get a Quote