PXI-2554
May 27, 2026

PXI-2554

I. Product Introduction The PXI-2554 is a 3U PXI 4×1 (SP4T) RF multiplexer module launched by National Instruments (NI), with part number 778572-54. It is specifically designed for 75 Ω RF systems, covering DC to 2.5 GHz, integrating a single bank and 4-channel electromechanical relays. It is suitable for signal switching and multi-channel testing in video/CATV, satellite communication, and 75 Ω RF equipment. Its main features include 75 Ω impedance matching, low loss, high isolation, and long lifespan.

Description

II. Model Interpretation

PXI: Compliant with the PXI bus standard, compatible with PXIe hybrid slots

2554: The serial number of the NI RF multiplexer series, representing 2.5 GHz, 75 Ω, 4×1 (SP4T), electromechanical relays

Alias: NI-2554, 4×1 Mux, SP4T RF Switch, 75 Ω Video Multiplexer

Position: 75 Ω dedicated, 4-out-of-1 RF multiplexer, suitable for broadcasting / video RF scenarios, single-slot high-density integration.

III. Technical Parameters Basic parameters

Topology: 4×1 multiplexer (SP4T), 4 input channels (CH1 to CH4) switched to 1 common output channel (COM) NI

Relay type: Electromechanical latch relay (EMR)

Frequency range: DC to 2.5 GHz (–3 dB)

Characteristic impedance: 75 Ω (nominal)

Channel configuration: 1 bank, 4 input channels, 1 output channel

RF performance (typical / guaranteed values)

Insertion loss:

≤1 GHz: <0.8 dB (typical <0.5 dB)

≤2 GHz: <1.3 dB (typical <0.9 dB)

≤2.5 GHz: <1.7 dB (typical <1.2 dB)

Channel-to-channel isolation NI:

≤1 GHz: >47 dB

≤2 GHz: >40 dB

≤2.5 GHz: >40 dB

VSWR:

≤2.5 GHz: <1.75 (typical <1.5)

Maximum switching power: 10 W (continuous) NI

Propagation delay: typical 1.0 ns NI

Rise time (10%–90%): typical 75 ps NI

Channel skew: typical <25 ps NI

Electrical and dynamic

Maximum switching voltage: 30 VDC NI

Maximum switching current: 0.5 A (per channel) NI

Maximum carrying current: 0.5 A (per channel) NI

Switching time: maximum 10.4 ms NI

Relay lifespan NI:

Mechanical lifespan: 1×10⁶ times

Electrical lifespan (30 V, 10 mA, DC resistive): 3×10⁵ times

Scan rate: maximum approximately 95 times/second

Physical and environment

I/O connector: 5×SMA female (4×CH + 1×COM, gold-plated)

Size: 3U PXI single slot (21.6 × 2.0 × 13.0 cm)

Weight: approximately 204 g

Power consumption: 12 V ≈ 0.4 W

Operating temperature: 0 to 55 °C

Storage temperature: –20 to 70 °C

Relative humidity: 5% to 85%, no condensation

IV. Interface and communication configuration

Front-end interface

RF interface: 5×SMA female

CH1 to CH4: 4 RF input channels (75 Ω)

COM: common output terminal (75 Ω)

Trigger interface: PXI backplane trigger line 0 to 7, minimum pulse width 150 ns NI

Bus and control

Bus interface: standard 3U PXI mixed bus (compatible with PXIe mixed slot)

Control software: compatible with NI- SWITCH, MAX, LabVIEW, TestStand, Switch Executive

Driver support: IVI compatible driver, provides LabVIEW VI and text language API

Trigger synchronization: PXI hardware trigger, multi-module cascading synchronization

Configuration method: software selects any one of the 4 channels to connect to COM, supports single-step switching and sequential scanning

Adaptation and expansion

Adaptation cable: SMA-SMA (75 Ω); optional SMA to BNC (75 Ω)

Expansion capability: multi-module cascading, builds N×1 multiplexer or 4×N matrix

V. Core functions

4×1 multiplexer (SP4T): 4 75 Ω RF signals selected to a single COM, realizes multi DUT / instrument sharing of a single port, simplifies test topology. DC - 2.5 GHz Broadband Coverage: Covers CATV (5 - 1000 MHz), satellite intermediate frequency, high-definition video, and ISM frequency bands, suitable for mainstream 75 Ω RF applications.

75 Ω Precise Impedance Matching: The entire system is designed with 75 Ω, eliminating impedance mismatch reflections, protecting the 75 Ω source end and DUT, and improving test accuracy.

Low Loss + High Isolation + Excellent VSWR: Low insertion loss, high channel isolation, small standing wave ratio, minimizing signal attenuation and crosstalk.

Relay Life Monitoring: On-board counter tracks the number of each channel switch, predicting lifespan, reducing unplanned downtime.

PXI Standard Integration + Low Power Consumption: Single slot 3U size, seamless integration into PXI chassis; latch relay design, no continuous power supply after switching, low heat generation.

Six, Application Scenarios

CATV / Broadcasting Equipment Testing: Multi-channel switching and parameter testing for 75 Ω RF ports of set-top boxes, modulators, amplifiers, distributors, etc.

Video RF Signal Routing: Selective routing and distribution of high-definition video, satellite intermediate frequency, and monitoring RF signals, preventing reflection damage to the source end.

75 Ω RF Component Verification: Function and mass production testing of filters, mixers, attenuators, antennas, etc., 75 Ω components.

Parallel Testing of Multiple DUTs: 4 75 Ω DUTs share one instrument (spectrum analyzer / network analyzer), improving test efficiency.

Research and Development Laboratory and Scheme Verification: Debugging, matching test of 75 Ω RF links, multiple scheme comparison, low reflection to ensure accuracy.

Seven, Usage and Maintenance Instructions

Usage Tips

Installation: Standard 3U PXI single slot, lock the panel, ensure reliable contact of the backplane; avoid strong vibration and electromagnetic interference.

Connection: SMA connector is lightly inserted and removed; RF power ≤ 10 W (continuous),严禁 exceeding power; unused ports are recommended to be connected to 75 Ω terminators.

Power On Status: Default no channel connection (COM open), need software to specify CHx → COM connection.

Software Control: Use NI-SWITCH or LabVIEW VI to select channels; regularly read relay counters to monitor remaining lifespan.

Environment: 0 - 55 °C operation, dust-proof, moisture-proof, and dew-proof; away from strong electromagnetic interference, ensure good grounding.

Maintenance Instructions

Regular Inspection: Quarterly inspection of SMA connectors for looseness, oxidation, or damage; clean the panel and ventilation ports, maintain good heat dissipation.

Life Management: Mechanical life is approximately 1 million times; regularly read onboard counters, plan for replacement in advance to avoid downtime.

Fault Troubleshooting: First check SMA connection, 75 Ω terminators and grounding; use MAX diagnostic switch status; take precautions against static electricity.

Storage: Power off when not in use, cover SMA with dust cap, dry and dust-proof storage, avoid high temperature, high humidity and strong magnetic fields.

Calibration: Suggested to calibrate once a year to ensure insertion loss, isolation, VSWR, etc., meet specifications; can contact NI or third-party calibration institutions.