330100-90-05
Description
Core function
Electromagnetic eddy current signal conditioning provides high-frequency excitation to the probe and outputs a voltage signal proportional to the clearance.
Used for monitoring shaft vibration, shaft displacement, eccentricity, and keyway signals.
Compatible with 3300 XL 8mm probe (such as 330101 series)
Electrical parameters
Power supply: -17.5 ~ -26VDC (typical -24VDC)
Sensitivity: 7.87 V/mm (200 mV/mil)
Linear range: 0.25 ~ 2.3 mm
Frequency response: 0 ~ 10 kHz
System impedance: 50 Ω
Mechanical and environmental
Material: Stainless steel housing
Operating temperature: -40°C ~ +85°C
Protection level: IP67
Weight: Approximately 0.29 kg
Matching components
Probe: 330101 series (8mm)
Extension cable: 330130 series
Monitoring module: 3500/40, 3500/42 Certification
CE, RoHS, SIL2/3, API 670 Application
Rotating machinery TSI protection and monitoring system for steam turbines, compressors, generators, etc.
Get a Quote